Diss Factsheets

Administrative data

First-aid measures

Emergency measure - Inhalation: Move person to fresh air; if effects occur, consult a

physician.

Emergency measure - Eyes: Flush eyes thoroughly with water for several minutes. Remove

contact lenses after the initial 1-2 minutes and continue

flushing for several additional minutes. If effects occur,

consult a physician, preferably an ophthalmologist.

Emergency measure - Skin: Wash skin with plenty of water.

Emergency measure - Ingestion: If swallowed, seek medical attention. Do not induce vomiting

unless directed to do so by medical personnel.

Fire-fighting measures

Recommended extinguishing agent: Water fog or fine spray. Dry chemical fire extinguishers.

Carbon dioxide fire extinguishers. Foam. Do not use direct

water stream. May spread fire. Alcohol resistant foams (ATC

type) are preferred. General purpose synthetic foams

(including AFFF) or protein foams may function, but will be

less effective.

Product arising from burning: During a fire, smoke may contain the original material in

addition to combustion products of varying composition which

may be toxic and/or irritating. Combustion products may

include and are not limited to: Carbon monoxide. Carbon

dioxide.

Product determined by test: N

Protective equipment: Wear positive-pressure self-contained breathing apparatus

(SCBA) and protective fire fighting clothing (includes fire

fighting helmet, coat, trousers, boots, and gloves). If

protective equipment is not available or not used, fight

fire from a protected location or safe distance.

Accidental release measures

Emergency measures in case of spillage: Contain spilled material if possible. Absorb with materials

such as: Dirt. Sand. Sawdust. Collect in suitable and

properly labeled containers.

Wash the spill site with water.

Personal Precautions: Isolate area. Keep unnecessary and

unprotected personnel from entering the area. Spilled

material may cause a slipping hazard. Use appropriate safety

equipment.

Environmental Precautions: Prevent from entering into soil,

ditches, sewers, waterways and/or groundwater.

Handling and storage

Handling: General Handling: Avoid contact with eyes. Wash thoroughly

after handling.

Other Precautions: Spills of these organic materials on hot

fibrous insulations may lead to lowering of

the autoignition temperatures possibly resulting in

spontaneous combustion.

Storage: Store in the following material(s): Carbon steel. Stainless

steel. Polypropylene. Polyethylene-lined container. Teflon.

Glass-lined container. Aluminum. Plasite 3066 lined

container. Plasite 3070 lined container. 316 stainless

steel.

Shelf life:

Use within  24 Months

Storage temperature: 20 - 60 °C

Packaging of the substance and or preparation: 216.5 liter capacity steel drums, suitable for packing

miscellaneous liquid chemicals.

bulk shipments

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: not classified for any mode of transportation
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: During fire:

Container may rupture from gas generation in a fire

situation.

Violent steam generation or eruption may occur upon

application of direct water stream to hot liquids

Chemical reaction with water: none

Dust explosion: not applicable - liquid

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: not applicable

Industry - Possibility of neutralisation: not applicable

Industry - Possibility of destruction: controlled discharge: not applicable

Industry - Possibility of destruction - incineration: recommended - energy recovery

Industry - Possibility of destruction - water purification: not applicable

Industry - Possibility of destruction - other: none

Public at large - Possibility of recovery/recycling: not applicable

Public at large - Possibility of neutralisation: not applicable

Public at large - Possibility of destruction: controlled discharge: not applicable

Public at large - Possibility of destruction - incineration: not applicable

Public at large - Possibility of destruction - water purification: not applicable

Public at large - Possibility of destruction - others: not applicable