Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 611-033-0 | CAS number: 536759-91-8
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Particle size distribution (Granulometry)
Administrative data
Link to relevant study record(s)
- Endpoint:
- particle size distribution (granulometry)
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- Experimental Starting Date: 25 April 2014 Experimental Completion Date: 03 June 2014
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: see 'Remark'
- Remarks:
- Study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of the relevant results. The study report was conclusive, done to a valid guideline and the study was conducted under GLP conditions.
- Qualifier:
- according to guideline
- Guideline:
- other: European Commission Guidance Document EUR 20268 ‘Determination of Particle Size Distribution, Fibre Length and Diameter Distribution of Chemical Substances’, 2002.
- Deviations:
- no
- Principles of method if other than guideline:
- ‘Determination of Particle Size Distribution, Fibre Length and Diameter Distribution of Chemical Substances’, 2002 via Cascade Impactor.
- GLP compliance:
- yes
- Type of method:
- cascade impaction
- Type of particle tested:
- primary particle
- Type of distribution:
- volumetric distribution
- Remarks on result:
- other: Too few particles were of a size less than 10.0 µm to allow accurate assessment of mass median aerodynamic diameter.
- Percentile:
- other: Too few particles were of a size less than 10.0 µm to allow accurate assessment of mass median aerodynamic diameter.
- Mean:
- other:
- Remarks on result:
- not determinable
- No.:
- #1
- Size:
- < 100 other: µm
- Distribution:
- 98.3 %
- No.:
- #2
- Size:
- < 10 other: µm
- Distribution:
- 0.101 %
- No.:
- #3
- Size:
- < 5.5 other: µm
- Distribution:
- 0.019 %
- Conclusions:
- Particle size data acquired for the test item:
Percentage of test item with an inhalable particle size <100 µm: 98.3% (sieve)
Percentage of test item with a thoracic particle size <10.0 µm: 0.101% (Cascade Impactor)
Percentage of test item with a respirable particle size <5.5 µm: 1.95 x 10-2% (Cascade Impactor) - Executive summary:
The determination was carried out using a procedure designed to be compatible with that given in European Commission Guidance Document EUR 20268 ‘Determination of Particle Size Distribution, Fibre Length and Diameter Distribution of Chemical Substances’, 2002.
Sieving Apparatus (Screening Test)
Instrument : Inclyno Sieve Shaker, Model No 1
Screening particle size: 100 µmTest conditions : Sieving for a period of approximately 30 minutes.
Cascade Impactor
Instrument : MSP Corporation, Marple Miller 160 Cascade Impactor
Particle size range : 0.3 to 10 µm.
Test conditions : Air flow of approximately 60 liters/minute.
Conclusion
Particle size data acquired for the test item is shown in the following table:
Table 3.20
Measurement
Method
Result
Percentage of test item with an inhalable particle size <100 µm
Sieve
98.3%
Percentage of test item with a thoracic particle size <10.0 µm
Cascade Impactor
0.101%
Percentage of test item with a respirable particle size <5.5 µm
Cascade Impactor
1.95 x 10-2%
Reference
Results
Sieve Screening Test
The results of the sieving procedure are shown in the following table:
Table 3.17
Measurement |
Result |
Mass of test item transferred to sieve |
12.07 g |
Mass of test item passed through sieve |
11.86 g |
Percentage of test item less than 100 µm |
98.3 % |
Cascade Impactor
The results of the cascade impactor procedure are shown in the following table:
Table 3.18
Collection Stage |
Particle Size Range Collected (µm) |
Collected Mass (g) |
||
Determination 1 |
Determination 2 |
Determination 3 |
||
Artificial throat |
n/a |
0.13 |
0.15 |
0.18 |
Cup 1 |
>10.0 |
3.2688 |
3.6525 |
3.6391 |
Cup 2 |
5.5 to 10.0 |
0.0028 |
0.0030 |
0.0032 |
Cup 3 |
2.4 to 5.5 |
0.0002 |
0.0002 |
0.0006 |
Cup 4 |
1.61 to 2.4 |
0.0009 |
0.0001 |
0.0000 |
Cup 5 |
0.307 to 1.61 |
0.0000 |
0.0000 |
0.0001 |
Final Filter |
<0.307 |
0.0000 |
0.0000 |
0.0000 |
Total mass of collected test item |
3.4027 |
3.8058 |
3.8230 |
The cumulative amounts of test item collected in the three determinations for the individual particle size cut-points are shown in the following table:
Table 3.19
Particle Size Cut Points (µm) |
Cumulative Mass (g) |
Cumulative Percentage (%) |
||||
Determination 1 |
Determination 2 |
Determination 3 |
Determination 1 |
Determination 2 |
Determination 3 |
|
<10.0 |
0.0039 |
0.0033 |
0.0039 |
0.115 |
8.67 x 10-2 |
0.102 |
<5.5 |
0.0011 |
0.0003 |
0.0007 |
3.23 x 10-2 |
7.88 x 10-3 |
1.83 x 10-2 |
<2.4 |
0.0009 |
0.0001 |
0.0001 |
2.65 x 10-2 |
2.63 x 10-3 |
2.62 x 10-3 |
<1.61 |
0.0000 |
0.0000 |
0.0001 |
- |
- |
2.62 x 10-3 |
<0.307 |
0.0000 |
0.0000 |
0.0000 |
- |
- |
- |
Mean cumulative percentage with a particle size less than 10.0 µm : 0.101%
Mean cumulative percentage with a particle size less than 5.5 µm : 1.95 x 10-2%
Description of key information
Particle size data acquired for the test item:
Percentage of test item with an inhalable particle size <100 µm: 98.3% (sieve)
Percentage of test item with a thoracic particle size <10.0 µm: 0.101% (Cascade Impactor)
Percentage of test item with a respirable particle size <5.5 µm: 1.95 x 10-2% (Cascade Impactor)
Additional information
Too few particles were of a size less than 10.0 µm to allow accurate assessment of the mass median aerodynamic diameter. however, the 50% mass point is between 10 and 100μm.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.