Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Between 23 January 2009 and 27 February 2009.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of the relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Date of GLP inspection: 19/08/2008 Date of Signature on GLP certificate: 04/03/2009
Type of method:
other: Differential Scanning Calorimetry, using ASTM E537-86

Test material

Constituent 1
Details on test material:

- Name of test material (as cited in study report): Eldew APS-307
- Substance type: Organic UVCB
- Physical state: Pale yellow waxy solid
- Analytical purity: 100%
- Lot/batch No.: 809114
- Stability under test conditions: stable
- Storage condition of test material: Room temperature, in the dark

Results and discussion

Melting / freezing point
Melting / freezing pt.:
304 - 321 K

Any other information on results incl. tables

Thermographic data for Determinations 1, 2 and 3 are shown in the following tables respectively:

Table 4.2:       Thermographic Data - Determination 1

 

Thermal Event

 

 

Interpretation

 

 

                 Temperature

                    oC

              K

 

Onset of endotherm

 

 

Onset of melting temperature range

 

32.05

305

   Endset of endotherm

 Endset of melting temperature range

47.69

321

Table 4.3:       Thermographic Data - Determination 2

 

Thermal Event

 

 

Interpretation

 

 

                 Temperature

                    oC

              K

 

Onset of endotherm

 

 

Onset of melting temperature range

 

31.06

304

   Endset of endotherm

 Endset of melting temperature range

46.94

320

Table 4.4:       Thermographic Data - Determination 3

 

Thermal Event

 

 

Interpretation

 

 

                 Temperature

                    oC

              K

 

Onset of endotherm

 

 

Onset of melting temperature range

 

30.58

304

   Endset of endotherm

 Endset of melting temperature range

47.05

320

Overall melting temperature range: 304 to 321 ± 1 K

Please see Attachment 1 for Thermogram data.

Applicant's summary and conclusion

Conclusions:
The melting temperature range of the test material has been determined to be 304 to 321 ± 1 K
Executive summary:

Method:

The determination was carried out by differential scanning calorimetry (DSC) using the procedure specified in ASTM E537-86, Method A1 Melting/Freezing Temperature of Council Regulation (EC) No 440/2008 of 30 May 2008.

Conclusion: The melting temperature range of the test material has been determined to be 304 to 321 ± 1 K