Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
skin irritation: in vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
March 2002
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: The study was conducted according to an OECD guideline, but GLP information is missing.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Report date:
2002

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 404 (Acute Dermal Irritation / Corrosion)
GLP compliance:
not specified

Test material

Constituent 1
Reference substance name:
DDH
IUPAC Name:
DDH
Details on test material:
Sample:DDH
Y our reference: 943510
Our reference: 202032

Test animals

Species:
rabbit
Strain:
New Zealand White
Details on test animals or test system and environmental conditions:
Observation period: 3 days
Temperature: 20° c (± 3°)
Relative humidity: 30-70%
Lighting: 12 hours light /12 hours darkness
Feeding: Conventional feeding
body weight: 2 kg to 3 kg.



Test system

Type of coverage:
not specified
Preparation of test site:
clipped
Vehicle:
not specified
Controls:
not specified
Amount / concentration applied:
Dose: 0,5 ml of the product.
Test material was administered to an area of 6 cm2 of clipped intact skin for 4
hours.
Duration of treatment / exposure:
4 h
Observation period:
72 h
Number of animals:
3 albino male rabbits

Results and discussion

In vivo

Results
Irritation parameter:
overall irritation score
Basis:
mean
Time point:
other: 4 h
Score:
0
Max. score:
0

Applicant's summary and conclusion

Interpretation of results:
not irritating
Remarks:
Migrated information Criteria used for interpretation of results: EU
Conclusions:
The product analysed does not cause any edema nor erythema which could be
detected after the 4 hours of contact of the sample within the test experimentation
conditions.
Non corrosive and non irritant product by skin contact.