Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Guideline study obtained through inquiry process; SNIF file obtained from ECHA.

Data source

Reference
Reference Type:
other: SNIF
Title:
Unnamed
Year:
1997

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
not specified
GLP compliance:
yes

Test material

Constituent 1
Reference substance name:
Body responsible for the test
IUPAC Name:
Body responsible for the test
Test material form:
not specified

Results and discussion

Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record. | Remarks: | Additional remarks: Test with a hot flame of a gas burner results in melting of the substance. The substance does not catch fire, neither unmelted nor melted.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record. | Remarks: | Additional remarks: Test with a hot flame of a gas burner results in melting of the substance. The substance does not catch fire, neither unmelted nor melted.
Substances / mixtures which in contact with water emit flammable gases
Remarks on result:
no reaction with water observed
Remarks:
corresponding to 'no' in migrated source record.| Remarks: | Additional remarks: Test A12 was not conducted as it is known from experience gained in use and also the chemistry of the substance, that it will not evolve frammable gases following contact with water and or humid air.

Any other information on results incl. tables

Tests A9 and A11 were not conducted as they are not applicable to a solid substance.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
The test substance was found to be non-flammable under the conditions of the test.
Executive summary:

The test substance has been determined to be non flammable in a GLP study according to EU Method A.10.