Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012-02-14 to 2012-02-14
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 170 Dry Sieve Analysis of Water Dispersible Granules, CIPAC Handbook Volume F, 1995
Deviations:
no
Principles of method if other than guideline:
Sieve analysis consists of the quantitative separation of water dispersible granules into fractions of different particle size ranges by use of machine sieving method.
GLP compliance:
yes (incl. QA statement)
Type of method:
sieving
Type of distribution:
other: Sieve analysis
Key result
Percentile:
D95
Mean:
> 1 000 µm
Remarks on result:
other: no standard deviation was determined

The particle size distribution of the ditetradecyl peroxydicarbonate was determined to be [1000 µm, > 4000 µm]. 80 % or more of the mass of the test item was in this range.

Conclusions:
The particle size distribution of ditetradecyl peroxydicarbonate was assessed according the CIPAC MT 170 guideline. Using the dry sieve analysis method the particle size distribution of ditetradecyl peroxydicarbonate was determined to be [1000 µm, > 4000 µm].
Executive summary:

The particle size distribution of ditetradecyl peroxydicarbonate was assessed according the CIPAC MT 170 guideline. Using the dry sieve analysis method the particle size distribution of ditetradecyl peroxydicarbonate was determined to be [1000 µm, > 4000 µm].

Description of key information

The particle size distribution of ditetradecyl peroxydicarbonate was assessed according the CIPAC MT 170 guideline. Using the dry sieve analysis method the particle size distribution of ditetradecyl peroxydicarbonate was determined to be in the range from 1000 µm to > 4000 µm.

Additional information

The particle size distribution of ditetradecyl peroxydicarbonate was assessed according the CIPAC MT 170 guideline. Using the dry sieve analysis method the particle size distribution of ditetradecyl peroxydicarbonate was determined to be in the range from 1000 µm to > 4000 µm.