Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
November 27th, 2012 - April 7th, 2013
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
Version / remarks:
(2008)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling point/boiling range)
Version / remarks:
(1995)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7220 (Boiling Point / Boiling Range)
Version / remarks:
(1996)
Deviations:
no
GLP compliance:
yes
Type of method:
differential scanning calorimetry
Key result
Decomposition:
yes
Decomp. temp.:
275 °C
Remarks on result:
other: Decomp. temp: 548 K

Boiling of the test substance was not observed below the temperature at which decomposition started.

Conclusions:
The substance has no boiling temperature. Boiling of the test substance was not observed below the temperature at which decomposition started, i.e. at 275°C (differential scanning calorimetry in accordance with EC A.2, OECD 103 and EPA OPPTS 830.7220 and in compliance with GLP).

Description of key information

The substance has no boiling temperature.

Boiling of the test substance was not observed

below the temperature at which decomposition

started, i.e. at 275°C (differential

scanning calorimetry in accordance

with EC A.2, OECD 103 and

EPA OPPTS 830.7220 and in compliance with GLP).

Key value for chemical safety assessment

Additional information

No boiling point has been identified for this substance.