Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Justification for type of information:
Data is from experimental study report
Qualifier:
according to guideline
Guideline:
other: as mentioned below
Principles of method if other than guideline:
Redox titrations are based on a reduction-oxidation reaction between an oxidizing agent and a reducing agent. A potentiometer or a redox indicator is usually used to determine the endpoint of the titration. In permanganometry a slight faint persisting pink color signals the endpoint of the titration because of the color of the excess oxidizing agent potassium permanganate
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Contact with:
potassium permanganate
Key result
Sample tested:
other: not specified (migrated information) ml or mg of KMnO4
Parameter:
other: ml or mg of KMnO4
Result:
472.5 other: ml/100g
Remarks on result:
other: no other details available
Interpretation of results:
other: no oxidising properties
Conclusions:
Test chemical was observed to have no oxidising property.
Executive summary:

Test chemical was observed to have no oxidising property.

Description of key information

Test chemical was observed to have no oxidising property.

Key value for chemical safety assessment

Oxidising properties:
no

Additional information

Test chemical was observed to have no oxidising property.

Justification for classification or non-classification