Registration Dossier

Diss Factsheets

Manufacture, use & exposure

Uses by professional workers

Uses by professional workers

Registration/ Notification status for the use:
use registered according to REACH Article 10; total tonnage manufactured/imported >=10tonnes/year per registrant
Use name:
Use as heat transfer fluid (HTF) at professional sites
Contributing activity / technique for the environment
Name of activity / technique:
Widespread use of functional fluid (indoor/outdoor)
Environmental release category (ERC):
ERC9a: Widespread use of functional fluid (indoor)
ERC9b: Widespread use of functional fluid (outdoor)
Contributing activity / technique for workersopen allclose all
Name of activity / technique:
Closed transfer, Filling, Refilling and Emptying of the HFT system (outdoor)
Process category (PROC):
PROC 1: Chemical production or refinery in closed process without likelihood of exposure or processes with equivalent containment conditions
Name of activity / technique:
Closed transfer, Filling, Refilling and Emptying of the HFT system (indoor)
Process category (PROC):
PROC 1: Chemical production or refinery in closed process without likelihood of exposure or processes with equivalent containment conditions
Name of activity / technique:
Closed transfer, Top up of the HTF system (outdoor)
Process category (PROC):
PROC 1: Chemical production or refinery in closed process without likelihood of exposure or processes with equivalent containment conditions
Name of activity / technique:
Closed transfer, Top up of the HTF system (indoor)
Process category (PROC):
PROC 1: Chemical production or refinery in closed process without likelihood of exposure or processes with equivalent containment conditions
Name of activity / technique:
Storage of the substance in storage tank
Process category (PROC):
PROC 1: Chemical production or refinery in closed process without likelihood of exposure or processes with equivalent containment conditions
Name of activity / technique:
Storage of the substance in drums and IBC
Process category (PROC):
PROC 1: Chemical production or refinery in closed process without likelihood of exposure or processes with equivalent containment conditions
Name of activity / technique:
Running of the HTF system (outdoor)
Process category (PROC):
PROC 1: Chemical production or refinery in closed process without likelihood of exposure or processes with equivalent containment conditions
Name of activity / technique:
Running of the HTF system (indoor)
Process category (PROC):
PROC 1: Chemical production or refinery in closed process without likelihood of exposure or processes with equivalent containment conditions
Name of activity / technique:
Sampling
Process category (PROC):
PROC 9: Transfer of substance or mixture into small containers (dedicated filling line, including weighing)
Product category used:
PC 16: Heat transfer fluids
Sector of end use:
SU 0: Other: various SUs
Subsequent service life relevant to this use:
no
Related assessment:
use assessed in an own CSR