Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Biodegradation in water: screening tests

Currently viewing:

Administrative data

Endpoint:
biodegradation in water: ready biodegradability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1990

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 301 F (Ready Biodegradability: Manometric Respirometry Test)
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
α,α,α,2-tetrachlorotoluene
EC Number:
218-377-7
EC Name:
α,α,α,2-tetrachlorotoluene
Cas Number:
2136-89-2
Molecular formula:
C7H4Cl4
IUPAC Name:
1-chloro-2-(trichloromethyl)benzene
Specific details on test material used for the study:
purity 99.4%

Study design

Oxygen conditions:
aerobic
Inoculum or test system:
activated sludge, industrial, non-adapted
Details on inoculum:
Inoculum concentration 100mg/L
Duration of test (contact time):
28 d
Initial test substance concentration
Initial conc.:
30 mg/L
Based on:
test mat.
Parameter followed for biodegradation estimation
Parameter followed for biodegradation estimation:
O2 consumption
Reference substance
Reference substance:
aniline

Results and discussion

% Degradation
Parameter:
% degradation (O2 consumption)
Value:
11
Sampling time:
28 d

BOD5 / COD results

Results with reference substance:
83% biodegradation, based on oxygen consumption

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Interpretation of results:
not readily biodegradable
Conclusions:
The test item is not readily biodegradable.