Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 218-377-7 | CAS number: 2136-89-2
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Partition coefficient
Administrative data
- Endpoint:
- partition coefficient
- Type of information:
- (Q)SAR
- Adequacy of study:
- weight of evidence
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- results derived from a valid (Q)SAR model and falling into its applicability domain, with adequate and reliable documentation / justification
- Justification for type of information:
- 1. SOFTWARE
EPIsuite 4.1 2012
2. MODEL (incl. version number)
KOWWIN 1.68
3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL
Clc1ccccc1C(Cl)(Cl)Cl
4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
- Defined endpoint: octanol water partiton coeffcient
- Unambiguous algorithm: yes, the algorithm is based on an atom/fragment contribution method
The log P = Σ(fini ) + Σ(cjnj ) + 0.229 where where Σ(fini ) is the summation of fi (the coefficient for each atom/fragment) times ni (the number of times the atom/fragment occurs in the structure); Σ(cjnj ) is the summation of cj (the coefficient for each correction factor) times nj (the number of times the correction factor occurs (or is applied) in the molecule) and 0.229 is the linear equation constant.
- Defined domain of applicability: Currently there is no universally accepted definition of model domain. However, users may wish to consider the possibility that log P estimates are less accurate for compounds outside the MW range of the training set compounds, and/or that have more instances of a given fragment than the maximum for all training set compounds. It is also possible that a compound may have a functional group(s) or other structural features not represented in the training set, and for which no fragment coefficient was developed. These points should be taken into consideration when interpreting model results.
- Appropriate measures of goodness-of-fit and robustness and predictivity: The training set statistics are as follows:
number in dataset = 2447
correlation coef (r2) = 0.982
standard deviation = 0.217
absolute deviation = 0.159
avg Molecular Weight = 199.98
The training set estimation error shows >95% of estimates are within 0.5 of the measured values of the training set
Training Set Estimation Error:
within <= 0.10 - 45.0%
within <= 0.20 - 72.5%
within <= 0.40 - 92.4%
within <= 0.50 - 96.4%
within <= 0.60 - 98.2%
KOWWIN has been tested on an external validation dataset of 10,946 compounds (compounds not included in the training set). The validation set includes a diverse selection of chemical structures that rigorously test the predictive accuracy of any model. It contains many chemicals that are similar in structure to chemicals in the training set, but also many chemicals that are different from and structurally more complex than chemicals in the training set.
Total Validation Set Statistics:
number in dataset = 10946
correlation coef (r2) = 0.943
standard deviation = 0.479
absolute deviation = 0.356
avg Molecular Weight = 258.98
Validation Set Estimation Error:
within <= 0.20 - 39.6%
within <= 0.40 - 66.0%
within <= 0.50 - 75.6%
within <= 0.60 - 82.5%
within <= 0.80 - 91.6%
within <= 1.00 - 95.6%
within <= 1.20 - 97.7%
within <= 1.50 - 99.1%
- Mechanistic interpretation: nort relevant for intrinsic pysical properties of substances
5. APPLICABILITY DOMAIN
- Descriptor domain: The substances falls within the molecular weight range of the training and validation datasets, close to the mean MW of both sets. The substance only contains molecular fragments contained in the model training set.
- Structural and mechanistic domains:
Log Kow(version 1.68 estimate): 4.54
SMILES : CLc1ccccc1C(CL)(CL)CL
CHEM :
MOL FOR: C7 H4 CL4
MOL WT : 229.92
-------+-----+--------------------------------------------+---------+--------
TYPE | NUM | KOW FRAGMENT DESCRIPTION | COEFF | VALUE
-------+-----+--------------------------------------------+---------+--------
Frag | 1 | C [aliphatic carbon - No H, not tert] | 0.9723 | 0.9723
Frag | 3 | -CL [chlorine, aliphatic attach] | 0.3102 | 0.9306
Frag | 6 | Aromatic Carbon | 0.2940 | 1.7640
Frag | 1 | -CL [chlorine, aromatic attach] | 0.6445 | 0.6445
Const | | Equation Constant | | 0.2290
-------+-----+--------------------------------------------+---------+--------
Log Kow = 4.5404
- Similarity with analogues in the training set: The substance only contains molecular fragments contained in the model training set.
6. ADEQUACY OF THE RESULT
The result can be considered adequate for risk assessment purposes as the prediction and model fulfil the OECD principlesfor QSAR.
Data source
Reference
- Reference Type:
- other: experimental database
- Title:
- EPISuite 4.1 KOWWIN Program v 1.68
- Author:
- US EPA
- Year:
- 2 012
- Bibliographic source:
- http://www.epa.gov/opptintr/exposure/pubs/episuitedl.htm
Materials and methods
Test guideline
- Qualifier:
- no guideline followed
- Principles of method if other than guideline:
- The partition coefficient value has been calculated using the KOWWIN 1.68 QSAR, part of the EPIWIN 4.1 Suite.
Test material
- Reference substance name:
- α,α,α,2-tetrachlorotoluene
- EC Number:
- 218-377-7
- EC Name:
- α,α,α,2-tetrachlorotoluene
- Cas Number:
- 2136-89-2
- Molecular formula:
- C7H4Cl4
- IUPAC Name:
- 1-chloro-2-(trichloromethyl)benzene
Constituent 1
Results and discussion
Partition coefficient
- Type:
- log Pow
- Partition coefficient:
- 4.54
- Temp.:
- 25 °C
- Remarks on result:
- other: QSAR (EPIWIN 4.1)
Applicant's summary and conclusion
- Conclusions:
- The log Pow of the test item is 4.54 at 25°C according to QSAR estimation (EPIWIN 4.10).
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.

EU Privacy Disclaimer
This website uses cookies to ensure you get the best experience on our websites.