Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2021
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
Laser scattering/diffraction
Type of particle tested:
aggregate
Type of distribution:
volumetric distribution
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source (i.e. manufacturer or supplier) and lot/batch number of test material: MLPC batch grad C 21022443262 & 21022443263 & 21022443264 & 21022443265 &21022443266
- melting point :respectively 131.1 & 131.8 & 131.4 & 130.7 & 131.0°C
- purity by HPLC : 96.8% -96.9- 96.9-96.9 -96.8%

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: 2 years

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing (e.g. warming, grinding): addition of 0.05g of NP6 for 0.5g of TbzTD C

FORM AS APPLIED IN THE TEST (if different from that of starting material)
- Specify the relevant form characteristics if different from those in the starting material, such as state of aggregation, shape of particles or particle size distribution: no


Key result
Percentile:
D10
Mean:
ca. 4.25 µm
St. dev.:
0.764
Key result
Percentile:
D50
Mean:
22.279 µm
St. dev.:
3.854
No.:
#3
Size:
< 30 µm
Distribution:
70 - 85 %
No.:
#2
Size:
< 20 µm
Distribution:
51 - 73 %
No.:
#1
Size:
< 10 µm
Distribution:
30 - 45 %

Mean values are listed in the table below. Variations due to repeatability are in the same order that these ones mentioned by ISO 13320-1 (3%).





































































 % below 10µm% below 20µm% below 30µmD0.1D(3.3)
2102244326233.7760.872.744.9424.765
2102244326330.4351.2770.564.03826.464
2102244326432.2457.54724.89523.608
2102244326538.9966.4480.654.30619.273
2102244326647.0573.2185.083.0717.287
Medium value36.49661.85276.2064.25022.279
St deviation6.7078.3926.3260.7643.854
Conclusions:
The mean particle size, number in volume, of TbzTD test item, is determined to be about 22 µm, with about 30-45% of particles presenting a diameter less than 10µm.
Executive summary:

A study was performed at Laboratoire Qualité & Soutien Exploitation de MLPC International to investigate the particle size distribution (granulometry) on 3 batchs of the test substance EKALAND ZBEC. The study was conducted according to ISO 13320- 1 “International standard for Laser Diffraction Measurements – Principles of Laser diffraction” and in accordance with OECD Test Guideline 110. The mean particle size, number in volume, of tbzTd test item, is determined to be 22 µm, with about 30-45% of particles presenting a diameter less than 10µm.

Description of key information

A study was performed at Laboratoire Qualité & Soutien Exploitation de MLPC International to investigate the particle size distribution (granulometry) on 3 batchs of the test substance EKALAND ZBEC. The study was conducted according to ISO 13320- 1 “International standard for Laser Diffraction Measurements – Principles of Laser diffraction” and in accordance with OECD Test Guideline 110. The mean particle size, number in volume, of tbzTd test item, is determined to be 22 µm, with about 30-45% of particles presenting a diameter less than 10µm.


 


 


 


 

Additional information