Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2008-08-07 to 2008-11-07
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
4 min
Remarks on result:
other: In the course of the preliminary test the test item could not be ignited. The test item melted. A main test was therefore not necessary.

The test item is not a highly flammable solid in the sense of the consolidated version of Council Directive 67/548/EEC Annex V (Council Directive 92/69/EEC), Method A. 10.

Interpretation of results:
GHS criteria not met
Conclusions:
Did not ignite during preliminary test. Not highly flammable
Executive summary:

Not highly flammable

Description of key information

Not highly flammable

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification