Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
density, other
Remarks:
absolute density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
09 Jul 2019
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2019
Report date:
2019

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
GLP compliance:
no
Type of method:
pycnometer method

Test material

Constituent 1
Chemical structure
Reference substance name:
Reaction mass of (((1,3-phenylenebis(oxy))bis(ethane-2,1-diyl))bis(oxy))bis(ethane-2,1-diyl) bis(2-methylacrylate) and (1,3-phenylenebis(oxy))bis(propane-3,1-diyl) bis(2-methylacrylate) and 3-(3-(2-(2-(methacryloyloxy)ethoxy)ethoxy)phenoxy)propyl methacrylaterate
EC Number:
944-271-1
Cas Number:
2305048-54-6
Molecular formula:
not applicable for multi-constituent.
IUPAC Name:
Reaction mass of (((1,3-phenylenebis(oxy))bis(ethane-2,1-diyl))bis(oxy))bis(ethane-2,1-diyl) bis(2-methylacrylate) and (1,3-phenylenebis(oxy))bis(propane-3,1-diyl) bis(2-methylacrylate) and 3-(3-(2-(2-(methacryloyloxy)ethoxy)ethoxy)phenoxy)propyl methacrylaterate
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Lot/batch number of test material: 653940

Results and discussion

Density
Key result
Type:
density
Density:
1.4 g/cm³
Temp.:
23 °C

Applicant's summary and conclusion

Conclusions:
The density of DiBrORMA was determined to be 1.40 g/cm³ at 23 °C.
Executive summary:

The density was determined using a stainless-steel pycnometer. The principles of the method used in this study are similar to a method of density measurement permitted by test guidance OECD 109 but was not GLP compliant. Therefore this study is considered reliable with restrictions.