Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
2021
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2021
Report date:
2021

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Constituent 1
Reference substance name:
Reaction mass of ethanol, 2-[[2-(2-hydroxyethoxy)ethyl]methylamino]- and 2,2'-(methylimino)diethanol
EC Number:
954-200-6
IUPAC Name:
Reaction mass of ethanol, 2-[[2-(2-hydroxyethoxy)ethyl]methylamino]- and 2,2'-(methylimino)diethanol

Results and discussion

Flash point
Key result
Flash point:
151 °C
Atm. press.:
1 013.25 hPa

Any other information on results incl. tables




















TestFlashpoint
in °C
Initial test150.0
1st Run *151.9
2nd Run*149.9

*Corrected flashpoint


The flashpoint of the test substance is 151.0 °C.

Applicant's summary and conclusion