Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Water solubility

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
26.04-04.05.2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.6 (Water Solubility)
Version / remarks:
European Commission Regulation (EC) No. 440/2008 and No. 260/2014
Deviations:
no
GLP compliance:
no
Type of method:
column elution method
Key result
Water solubility:
< 0.02 mg/L
Conc. based on:
test mat.
Temp.:
25 °C
pH:
> 5.6 - < 5.9

Preliminary test

Three preliminary tests were carried out with specified amounts of the test item and 100 ml and

500 ml demineralized water, respectively. After each addition of an amount of water, the mixture

was stirred for at least 24 hours, and visually checked for any undissolved particles.

 

 

Table: Results of the preliminary test

Amount of test item /mg

Total volume of demineralized water / mL

Appearance of mixture

15.4

100

Not dissolved

9.1

500

Not dissolved

3.8

500

Not dissolved

 

The preliminary test showed that the water solubility of the test item is < 10 mg/L. According to the preliminary test the water solubility was determined by the column elution method in the main test.

 

Column elution method

103.1 mg of the test item were dissolved in 100 mL in acetone. For charging the columns in each case 25 mL of the test item solution was added to about 3 g of sea sand and the mixtures were shaken. The solvent was then removed under reduced pressure using a rotary evaporator (40 °C, approx. 40 mbar). The dry residues were placed into the columns of the test apparatus, which have afterwards been filled with water (test temperature: 20 °C; water pH at 22 °C: 5.4). After a swelling time of 2 h pumps were started to rinse the test item coated sand with demineralized water. At the end of the study it was confirmed that residual test item remained on the columns. The residual test item was eluted with 50 mL acetone. The eluate was diluted from 0.1 mL to 10 mL and again from 0.5 mL to 1.0 mL with acetonitrile. As blank value demineralized water was tested. No signal was detected in the range of the retention time of the test item. The concentration of the test item was quantified by HPLC.

 

Column 1:

Rotation period of the fraction collector:          90 min per fraction

Duration of sampling:                           about 71 h (47 fractions)

 

Table column elution method, column 1 (approx. 12.5 mL/h)

Fraction no

V / mL

pH

Water solubility / µg/L

38

19.0

5.8

< 19.8

39

19.0

5.9

< 19.8

40

19.0

5.7

< 19.8

41

19.0

5.9

< 19.8

42

19.0

5.8

< 19.8

 

The water solubility was found to be below the quantification limit of 19.8µg/L.

 

Column 2:

Rotation period of the fraction collector:          45 min per fraction

Duration of sampling:                           about 71 h (94 fractions)

 

Table column elution method, column 2 (approx. 25.0 mL/h)

Fraction no

V / mL

pH

Water solubility / µg/L

80

17.5

5.6

< 19.8

81

17.0

5.8

< 19.8

82

17.5

5.9

< 19.8

83

17.0

5.7

< 19.8

84

17.0

5.8

< 19.8

 

The water solubility was found to be below the quantification limit of 19.8µg/L.

 

In both columns the concentration of five consecutive fractions was constant within ± 30 %. No increasing or decreasing tendency was observed.

 

Table Coating check

 

Amount of test item

used for coating /mg

Measured concentration of

 test item in eluate /mg/L

Amount of test item

 eluated /mg

Column 12.5 mL/h

25.8

0.716 / 0.716

17.9

Column 25.0 mL/h

25.8

0.677 / 0.676

16.9

 

The coating check was successful. Enough test item remained on the columns. The water solubility cs of the test item was below the quantification limit of < 19.8 µg/L (mean value of the columns) in both columns.

Conclusions:
The water solubility cs of the test item at a temperature of 20°C was determined according to the column elution method. It was found to be below the quantification limit: cs < 0.02 mg/L.
Executive summary:

The water solubility was determined according to OECD 105 using the column elution method. The preliminary test showed that the water solubility of the test item is < 10 mg/L. The column elution method showed a solubility: cs < 0.02 mg/L.

Description of key information

The water solubility cs of the test item at a temperature of 20°C was determined according to the column elution method was found to be cs < 0.02 mg/L.

Key value for chemical safety assessment

Additional information

The water solubility was determined according to OECD 105 using the column elution method. The preliminary test showed that the water solubility of the test item is < 10 mg/L. The column elution method showed a solubility below the quantification limit: cs < 0.02 mg/l