Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2020-02-10
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
440/2008/EC, 30 May 2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2016
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
non-equilibrium method closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
105.5 °C
Atm. press.:
1 013 hPa

Preliminary test

Amount of test item / g

Temperature / °C

Ignition (+/-)

Air pressure / hPa

65.93

105.3

+

983.9

In the preliminary test the lowest temperature where an ignition was observed was 105.3 °C.

Main test

Amount of test item / g

Temperature /
°C

Ignition /
(+/-)

Air pressure /
hPa

Corrected flash point / °C

65.92

105.1

+

985.2

105.8

65.32

104.9

+

988.9

105.5

The measured flash points are corrected to the ambient pressure and averaged to be 105.65 °C.

The resulting average corrected flash point rounded down to the nearest multiple of 0.5 °C is 105.5 °C.

Interpretation of results:
GHS criteria not met
Conclusions:
The flash-point of the test item was determined to be 105.5 °C.
Executive summary:

A study was conducted according to Regulation EC No. 440/2008 Method A.9. Flash Point andDIN EN ISO 2719 (2016)to determine the flash point of the test item using non-equilibrium closed cup method. A Pensky-Mertens apparatus was used for this purpose. The approximate flash point was determined in a preliminary test. The first ignition trial of the main test is performed at a test item temperature 23 ± 5 °C below the approximate flash point determined in the preliminary test. The flame is dipped in the cup at 1 K intervals. The main test was performed twice. The mean flash point corrected to standard pressure of 1013 hPa and rounded down to the nearest multiple of 0.5 °C was determined to be 105.5 °C.

Description of key information

The flash-point of the test item was determined to be 105.5 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
105.5 °C

Additional information

A study was conducted according to Regulation EC No. 440/2008 Method A.9. Flash Point andDIN EN ISO 2719 (2016)to determine the flash point of the test item using non-equilibrium closed cup method. A Pensky-Mertens apparatus was used for this purpose. The approximate flash point was determined in a preliminary test. The first ignition trial of the main test is performed at a test item temperature 23 ± 5 °C below the approximate flash point determined in the preliminary test. The flame is dipped in the cup at 1 K intervals. The main test was performed twice. The mean flash point corrected to standard pressure of 1013 hPa and rounded down to the nearest multiple of 0.5 °C was determined to be 105.5 °C.