First-aid measures

- General advice: First aider needs to protect himself. Move injured person out of dangerous area. Lie down unconscious person in the recovery position and cover to prevent hypothermia. Never give anything by mouth to an unconscious person. In the case of accident or if you feel unwell, seek medical advice immediately (show the label where possible).
- If inhaled: Remove to fresh air. Make the victim blow his nose. Oxygen or artificial respiration if needed. In case of problems, get medical advice.
- In case of skin contact: Wash off immediately with soap and plenty of water. Take off contaminated clothing and shoes immediately. In case of problems, get medical advice.
- In case of eye contact: Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Keep eye wide open while rinsing. If easy to do, remove contact lens, if worn. In case of problems, get medical advice.
- If swallowed: Rinse mouth with water. Do not induce vomiting without medical advice. In case of problems, get medical advice.

Fire-fighting measures

- Suitable extinguishing media: Water spray, Carbon dioxide (CO2), Dry powder, Alcohol-resistant foam
- Unsuitable extinguishing media: High volume water jet.
- Specific hazards during firefighting: Exposure to decomposition products may be a hazard for health.
In case of fire hazardous decomposition products may be produced such as: Carbon oxides.
- Special protective equipment for firefighters: Wear full protective clothing and self-contained breathing apparatus (SCBA).

- Further information for firefighters: In the event of fire and/or explosion do not breathe fumes. Collect contaminated fire extinguishing water separately. This must not be discharged into drains. Keep containers and surroundings cool with water spray.

Accidental release measures

- Personal precautions : Ensure adequate ventilation. Evacuate personnel to safe areas. Do not get in eyes or mouth or on skin. Avoid dust formation. Avoid breathing dust. Use personal protection equipment.
- Environmental precautions : Prevent further leakage or spillage. The product should not be allowed to enter drains, water courses or the soil.
- Methods for cleaning up : Pick up and transfer to properly labelled containers. Pick up and arrange disposal without creating dust. Clean contaminated surface thoroughly. If reuse of spilled substance/mixture is not possible, it should be disposed as hazardous waste.

Handling and storage

- Advice on safe handling : Ensure adequate ventilation. Avoid dust formation. Avoid breathing dust. Do not get in eyes or mouth or on skin. Wear personal protective equipment.
- Advice on protection against fire and explosion: Use only in area provided with appropriate exhaust ventilation. Avoid dust formation. Take measures to prevent the build-up of electrostatic charge. Ensure grounding of equipment and personnel (use of dissipative personal protective equipment). Risk of dust explosion.
- Hygiene measures : Do not get in eyes or mouth or on skin. Avoid breathing dust. Take off all contaminated clothing immediately. Wash hands and face before breaks and immediately after handling the product. When using do not eat, drink or smoke. Regular cleaning of equipment, work area and clothing. Handle in accordance with good manufacturing and safety practice.
- Storage conditions : Keep in a well-ventilated place. Keep container tightly closed. Protect from light, moisture and damage.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

- Protective measures : Keep it accessible to employees only. Ensure that eyewash stations and safety showers are close to the workstation location.
Personal protective equipment should be inspected prior to use and applied in accordance with the purpose and the manufacturer's instructions.
The type of protective equipment must be selected according to the exposure time and amount of the dangerous substance/mixture at the specific workplace.
When working with >10 kg of powder with high dustiness potential for more than 30 min or with >100 kg of powder with medium dustiness potential for more than 30 min:
Engineering and organizational protective measures:
Use of local exhaust ventilation with mechanical barrier or the same containment strategy equipment. All working surfaces should allow easy cleaning. Maintenance of outlet filter in a closed system. Closed cleaning system or multi-phase cleaning equipment. Only operators trained in emergency evacuation procedures are allowed to access the area. Wet cleaning and decontamination of full protective clothing.

The following personal protective equipment should be used:
protective suit, disposable protective clothing with protective head-covering, safety shoes (EN ISO 20345), disposable shoe covers, Protective gloves (EN 374), nitrile rubber gloves (thickness 0.15 mm), safety glasses with side-shields (EN166), dust respirator with filter P3 (EN 149)

Stability and reactivity

Reactivity:
No dangerous reaction known under conditions of normal use.

Chemical stability:
Stable under normal conditions.

Possibility of hazardous reactions:
No data available.

Conditions to avoid :
Dust may form explosive mixture in air. Take measures to prevent the build-up of electrostatic charge. Avoid excessive heat.

Incompatible materials:
Strong oxidizing agents.

Hazardous decomposition products:
No hazardous decomposition products are known.

Disposal considerations

Send waste substance/mixture to authorized collector for incineration under controlled conditions or appropriate disposal in accordance with local regulations.