Registration Dossier

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 30 July 2018 to 21 November 2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
GLP compliance:
yes
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Mass median aerodynamic diameter:
53.9 µm
Percentile:
D50
Mean:
ca. 53.9 µm
St. dev.:
1.12
No.:
#1
Size:
> 0 - <= 50 µm
Distribution:
55.42 %
No.:
#2
Size:
> 50 - <= 100 µm
Distribution:
39.85 %
No.:
#3
Size:
> 100 µm
Distribution:
4.73 %

Table 1. Particle Size Distribution of CR SR94

  Replicate 1 Replicate 2 Replicate 3
Particle size distribution (µm) 54.6 53.4 53.9
Mean Particle size distribution (µm) 53.9
RSD (%) 1.12%
Conclusions:
The mass median diameter is 53.9 μm.
Executive summary:

The determination of the Particle Size Distribution of CR SR94 was performed in accordance with OECD Guideline no. 110.

The method can only be applied to water-insoluble (<10^-6 g/L), powdered type products.

The Particle Size Distribution of CR SR94 was determined to be 53.9 μm.

Description of key information

The mass median diameter is 53.9 μm.

Additional information