Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
other information
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1999
Report date:
2001

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.6 (Water Solubility)
Version / remarks:
92/69/EEC
GLP compliance:
yes (incl. QA statement)
Type of method:
other: addition method

Test material

Test material form:
solid
Specific details on test material used for the study:
Purity: 95.6 % [w/w]

Results and discussion

Water solubility
Water solubility:
666 mg/L
Conc. based on:
test mat. (dissolved fraction)
Details on results:
Maen of two meassurements.

Applicant's summary and conclusion

Conclusions:
Under the conditions of this test the water solubility of Tetrakis(piperidon)phosphonium chloride was found to be 666 g/L.