Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 701-278-2 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Endpoint summary
Administrative data
Description of key information
The skin irritation and skin corrosion endpoints have been completed using GLP-compliant studies following OECD 439 and OECD 431 guidelines. The substance showed a cell viability of 96.4%, which is above the threshold for irritancy (≤50%) and consequently the test item was not irritant to skin. The test item was considered to be non-corrosive to skin as the viability of the cells was 97.7% after 3 minutes of exposure and 99.4% after 60 minutes exposure. The test substance did not meet the criteria for classification for skin irritation or corrosion.
No studies have been conducted for the eye irritation or eye corrosion endpoints. No data were identified which would indicate that the substance would meet the criteria for classification for eye irritation or corrosion and experimental data on a structural analogue support that the substance would not meet the criteria for classification.
Key value for chemical safety assessment
Skin irritation / corrosion
Link to relevant study records
- Endpoint:
- skin irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 13 April 2017 - 02 June 2017
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 439 (In Vitro Skin Irritation: Reconstructed Human Epidermis Test Method)
- Version / remarks:
- (Original Guideline adopted July 28, 2015)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Specific details on test material used for the study:
- SOURCE OF TEST MATERIAL
- Batch: A026/99 and A026/50-01
- Purity: 100% (UVCB)
- Appearance: White solid
- Expiration date: 01 July 2019
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: Room temperature - Test system:
- other: EPISKIN™ Reconstructed Human Epidermis Model
- Source species:
- other: EPISKIN™ Reconstructed Human Epidermis Model
- Cell type:
- non-transformed keratinocytes
- Cell source:
- other: EPISKIN™ Reconstructed Human Epidermis Model
- Source strain:
- other: EPISKIN™ Reconstructed Human Epidermis Model
- Details on animal used as source of test system:
- Source: EpiSkin™ model kit.
Supplier: EpiSkin™ kits are purchased from SkinEthic Laboratories (69007 Lyon, France).
EpiSkin™ Kit Lot No.: 17-EKIN-022 - Justification for test system used:
- In an international validation study performed by ECVAM, the in vitro skin irritation test using the human skin models EpiSkin™ and EpiDerm™ and measurement of cell viability by dehydrogenase conversion of MTT into a blue formazan salt have turned out as a sufficiently promising predictor for skin irritancy potential.
- Vehicle:
- unchanged (no vehicle)
- Details on test system:
- RECONSTRUCTED HUMAN EPIDERMIS (RHE) TISSUE
- Model used: EPISKIN™ Reconstructed Human Epidermis Model Kit
- Tissue batch number(s): 17-EKIN-022
- Delivery date: 30 May 2017
- Date of initiation of testing: 30 May 2017
TEMPERATURE USED FOR TEST SYSTEM
- Temperature used during treatment / exposure: 37°C
- Temperature of post-treatment incubation (if applicable): 37°C
REMOVAL OF TEST MATERIAL AND CONTROLS
- Volume and number of washing steps: Rinsing was achieved by filling and emptying each tissue using a soft stream of PBS to gently remove any residual test item
- Observable damage in the tissue due to washing: Not specified
- Modifications to validated SOP: None
MTT DYE USED TO MEASURE TISSUE VIABILITY AFTER TREATMENT / EXPOSURE
- MTT concentration: 2 mL assay medium containing 0.3 mg/mL MTT per well
- Incubation time: 3 hours
- Spectrophotometer: Microplate reader (Versamax® Molecular Devices, 85737 Ismaning, Germany, version 4.7.1)
- Filter: 570 nm
- Filter bandwidth: Not applicable
- Linear OD range of spectrophotometer: Not specified
FUNCTIONAL MODEL CONDITIONS WITH REFERENCE TO HISTORICAL DATA
- The results for the positive control are within the historical data (means, rel. standard deviation, and ranges) of Envigo CRS GmbH
- The results for the negative control are within the historical data (means, rel. standard deviation and ranges) of Envigo CRS GmbH (Please note: the study was performed by using PBS, the Historical Control Data Base annexed to the report shows the Data for deionized water; data for PBS are in process and the number of studies is still too low for presenting Historical Data). Comparing the results of PBS to the Historical Control Data Base generated with deionized water is legitimate since both controls are aqueous from the chemical point of view. In other toxicological studies (e.g. OECD 487 or OECD 473) Historical Data Bases distinguish only between aqueous or organic solvents.
NUMBER OF REPLICATE TISSUES: 3
CONTROL TISSUES USED IN CASE OF MTT DIRECT INTERFERENCE
- Since the colour did not turn blue/purple, the test item was not considered to be a MTT reducer. Therefore, it was not necessary to perform an additional test with freeze-killed tissues to determine a correction factor for calculating the true viability in the main experiment.
NUMBER OF INDEPENDENT TEST SEQUENCES / EXPERIMENTS TO DERIVE FINAL PREDICTION: Three
- Test for Direct MTT Reduction
- Test for Direct Colour Interference
- Main test
PREDICTION MODEL / DECISION CRITERIA
- The test substance is considered to be an irritant to skin if the relative mean tissue viability after a 15 minute exposure period followed by the 42-Hour post-exposure incubation period is less than or equal to 50%.
- The test substance is considered to be non-corrosive to skin if the viability after 15-Minute exposure period followed by the 42-Hour post-exposure incubation period is greater than 50%. - Control samples:
- yes, concurrent negative control
- yes, concurrent positive control
- Amount/concentration applied:
- TEST MATERIAL
- Amount applied: 5 μL of deionised water followed by 10 ± 2 mg of the test item were topically applied to the epidermal surface
- Concentration (if solution): Test material is a solid
VEHICLE
- Not applicable
NEGATIVE CONTROL
- Name: PBS (produced in-house: 40 g NaCl, 1 g KCl, 1 g KH2PO4, 0.94 g Na2HPO4 + 2 H2O filled to 5000 mL with deionised water)
- Amount(s) applied: 10 μL
- Concentration: Not specified.
POSITIVE CONTROL
- Name: 5% SLS (Fluka, Sigma-Aldrich) solution in deionised water
- Amount(s) applied: 10 μL
- Concentration (if solution): 5% w/v aqueous solution - Duration of treatment / exposure:
- 15 minutes
- Duration of post-treatment incubation (if applicable):
- The tissues were incubated for approximately 41.5 hours at 37 ± 1.5°C, 5 ± 0.5% CO2
- Number of replicates:
- 3 test replicates
- Species:
- other: reconstituted human epidermis model
- Strain:
- other: reconstituted human epidermis model
- Details on test animals or test system and environmental conditions:
- Not applicable
- Type of coverage:
- other: Topical
- Preparation of test site:
- other: Not applicable
- Vehicle:
- other: No vehicle used
- Controls:
- yes, concurrent positive control
- yes, concurrent negative control
- Amount / concentration applied:
- TEST MATERIAL
- Amount applied: 5 μL of deionised water followed by 10 ± 2 mg of the test item were topically applied to the epidermal surface
- Concentration (if solution): Test material is a solid
VEHICLE
- Not applicable
NEGATIVE CONTROL
- Name: PBS (produced in-house: 40 g NaCl, 1 g KCl, 1 g KH2PO4, 0.94 g Na2HPO4 + 2 H2O filled to 5000 mL with deionised water)
- Amount(s) applied: 10 μL
- Concentration: Not specified.
POSITIVE CONTROL
- Name: 5% SLS (Fluka, Sigma-Aldrich) solution in deionised water
- Amount(s) applied: 10 μL
- Concentration (if solution): 5% w/v aqueous solution - Duration of treatment / exposure:
- Treatment: The test item tissues were soaked in 5 μL of deionised water. The controls and test item was added into the insert above the EpiSkin™ triplicate tissues for 15 minutes. The post exposure incubation period was 42 hours.
- Observation period:
- Not applicable
- Number of animals:
- Not applicable
- Details on study design:
- TEST SITE
- Area of exposure: The test material was applied to a human reconstructed epidermis model. The epidermis surface had previously been moistened with 5 μL of distilled water to improve contact between the solid test material and the epidermis.
- % coverage: The test material was applied topically to the corresponding tissues ensuring uniform covering.
- Type of wrap if used: None used
REMOVAL OF TEST SUBSTANCE
- Washing: After the end of the treatment interval the inserts were immediately removed from the 12-well plate. The tissues were gently rinsed with PBS to remove any residual test material. Excess PBS was removed by gently shaking the inserts and blotting the bottom with blotting paper.
- Time after start of exposure: 15 Minutes
SCORING SYSTEM:
- Quantitative MTT Assessment (percentage tissue viability): For the test material, the relative mean tissue viabilities obtained after the 15 minute treatment followed by the 42-hour post-exposure incubation period were compared to the mean of the negative control treated tissues (n=3). The relative mean viabilities were calculated in the following way:
Relative mean tissue viability (percentage of negative control) = (mean OD570 of test material / mean OD570 of negative control) x 100
Classification of irritation potential is based upon relative tissue viability following the 15-minute exposure period followed by the 42-hour post-exposure incubation period according to the following:
Mean tissue viability is ≤50%: Irritant (I) H315 Category 2
Mean tissue viability is >50%: Non-Irritant (NI) Not classified. (Category 3 cannot be determined) - Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- Relative mean variability
- Value:
- 96.4
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Other effects / acceptance of results:
- The optical pre-experiment (colour interference pre-experiment) to investigate the test item’s colour change potential in water did not lead to a change in colour.
Optical evaluation of the MTT-reducing capacity of the test item after 3 hour incubation with MTT-reagent did not show blue colour.
The mean relative absorbance value of the test item, corresponding to the cell viability, decreased to 96.4% (threshold for irritancy: ≤ 50%), consequently the test item was not irritant to skin. - Interpretation of results:
- GHS criteria not met
- Conclusions:
- The test material was considered to be a non-irritant to skin using the EPISKIN™ Reconstructed Human Epidermis Model.
- Executive summary:
The study is assigned a reliability score of 1 (reliable without restrictions) as it followed OECD Guideline 439: In vitro Skin Irritation: Reconstructed Human Epidermis Test Method, is compliant with GLP and met the acceptance criteria. The substance, under test conditions, had a mean relative absorbance value, corresponding to cell viability, of 96.4%, which is above the threshold for irritancy (≤50%) and consequently the test item was not irritant to skin.
Reference
Quality Criteria
The acceptance criteria were met:
• the mean OD of the three negative control exposed tissues is ≥ 0.6 till ≤ 1.5 (range: 0.856 to 0.972).
• the rel. standard deviations between tissues of the same treatment group was ≤ 18% (range: 6.6 to 12.7%).
• the mean relative tissue viability of the positive control was ≤ 40% (5.3%).
• the acceptance limit of the IC50 of the respective EpiSkin™ lot was between 1.5 and 3.0 mg/mL after 18 hours treatment with SLS (1.7 mg/mL).
• the results for the positive control are within the historical data (means, rel. standard deviation, and ranges) of Envigo CRS GmbH
• the results for the negative control are within the historical data (means, rel. standard deviation and ranges) of Envigo CRS GmbH (Please note: the study was performed by using PBS, the Historical Control Data Base annexed to the report shows the Data for deionized water; data for PBS are in process and the number of studies is still too low for presenting Historical Data). Comparing the results of PBS to the Historical Control Data Base generated with deionized water is legitimate since both controls are aqueous from the chemical point of view. In other toxicological studies (e.g. OECD 487 or OECD 473) Historical Data Bases distinguish only between aqueous or organic solvents.
RESULTS
The individual and mean absorbance values, standard deviations and tissue viabilities for the test material, negative control material and positive control material are given in Table 1. The relative mean viability of the test material treated tissues was 96.4% after a 15 minutes exposure.
Table 1: Mean absorbance values and percentages for the blank control, negative control material, positive control material and test material.
Results after treatment with test item and controls
Test Group |
Absor-bance 570 nm |
Absor-bance 570 nm |
Mean Absor-bance 570 nm |
Mean Absor-bance 570 nm |
Mean Absor-bance of 3 Tissues |
Relative Absor-bance [%] Tissue 1, 2, 3** |
Relative Standard Deviation [%] |
Rel. Absor-bance [% of Negative Control]*** |
Blank |
0.038 |
0.038 |
0.038 |
|
||||
Negative Control |
0.945 |
0.905 |
0.925 |
0.887 |
0.880 |
100.8 |
6.6 |
100.0 |
0.983 |
0.960 |
0.972 |
0.934 |
106.2 |
||||
0.872 |
0.840 |
0.856 |
0.818 |
93.0 |
||||
Positive Control |
0.073 |
0.083 |
0.078 |
0.040 |
0.046 |
4.5 |
12.7 |
5.3 |
0.091 |
0.080 |
0.086 |
0.048 |
5.4 |
||||
0.087 |
0.091 |
0.089 |
0.051 |
5.8 |
||||
Test Item |
0.986 |
0.961 |
0.974 |
0.936 |
0.848 |
106.4 |
9.6 |
96.4 |
0.848 |
0.890 |
0.869 |
0.831 |
94.5 |
||||
0.832 |
0.794 |
0.813 |
0.775 |
88.1 |
Endpoint conclusion
- Endpoint conclusion:
- no adverse effect observed (not irritating)
Eye irritation
Endpoint conclusion
- Endpoint conclusion:
- no study available
Respiratory irritation
Endpoint conclusion
- Endpoint conclusion:
- no study available
Additional information
The skin irritation and skin corrosion endpoints have been completed using GLP-compliant studies following OECD 439 and OECD 431 guidelines. The test substance did not meet the criteria for classification for skin irritation or corrosion.
No studies have been conducted for the eye irritation or eye corrosion endpoints. A literature search and the available data for the substance did not identify any hazards and no data were identified which would lead to predictions that the substance would meet the criteria for classification for human or environmental effects under the CLP regulation. Therefore, the substance is not expected to meet the criteria for classification for eye irritation or corrosion and as the substance is being registered with reduced information requirements, as set out under REACH Annex III, no studies for eye irritation or corrosion were conducted.
Furthermore, the reaction mass of methyl N-octadecylterephthalamate and N,N'‑dioctadecylterephthalamide (with methyl N-octadecylterephthalamate, a structural analogue for sodium 4‑[(octadecylamino)carbonyl]benzoate) has been registered under REACH and does not meet the criteria for classification for human health or the environment. The replacement of the methyl functional group present in the source substance with the sodium ion present in the target is not expected to lead to a change in classification and therefore it is expected that the target substance would also not meet the criteria for classification.
Therefore, using experimental and read across data, it is concluded that Sodium 4-[(C16-18-(even numbered)-alkylamino)carbonyl]benzoate does not meet the criteria for classification for irritation or corrosion.
Justification for classification or non-classification
Experimental data are available to show that the substance would not meet the criteria for classification for skin irritation or corrosion. No data were identified which would indicate that the substance would meet the criteria for classification for eye irritation or corrosion. Furthermore, experimental data on a structural analogue support that the substance would not meet the criteria for classification. Therefore, it is concluded that Sodium 4-[(C16-18-(even numbered)-alkylamino)carbonyl]benzoate does not meet the criteria for classification for irritation or corrosion.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.