Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
October 4, 2007 - January 15, 2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study has been performed according to OECD and EC guidelines and according to GLP principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: by loss of weight or by trapping vaporisate

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): Corsair Clear #12
- Substance type: Soft waxy beige solid
- Physical state: Solid
- Stability under test conditions: stable
- Storage condition of test material: At room temperature in the dark

Results and discussion

Vapour pressure
Temp.:
20 °C
Vapour pressure:
< 0 Pa
Remarks on result:
other: The vapour pressure ranged between 1.38·10-6 Pa and 3.49·10-5 Pa

Applicant's summary and conclusion

Conclusions:
The isothermal thermogravimetric effusion method was chosen for the determination of the vapour pressure of Corsair Clear #12. The vapour pressure of the molten test substance extrapolated to 20°C (293K) ranged between 1.38 · 10-6 Pa (1.04 · 10-8 mm Hg) and 3.49 · 10-5 Pa (2.62 · 10-7 mm Hg).