Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
5/1/2018 to 21/5/2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Version / remarks:
11 July 2006
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: isothermal thermogravimetry

Test material

Constituent 1
Chemical structure
Reference substance name:
tridecyl 2-hydroxybenzoate
EC Number:
947-975-7
Molecular formula:
C20H32O3
IUPAC Name:
tridecyl 2-hydroxybenzoate
Specific details on test material used for the study:
Identification: Dermol TDSA
Appearance: Colourless to pale yellow clear liquid
Batch: P7202
Purity/Composition: UVCB
Test item storage: At room temperature
Stable under storage conditions until: 11 November 2021 (expiry date)
Additional information
Test Facility test item number: 209078/A
Purity/Composition correction factor: No correction factor required
Test item handling: No specific handling conditions required
Molecular structure: Not indicated
Molecular formula: C20H32O3
Molecular weight: 320
Test Item Characterization
The Sponsor provided to the Test Facility documentation of the identity, purity, composition, and stability for the test item(s). A Certificate of Analysis or equivalent document was provided to the Test Facility and is presented in Appendix 2.

Results and discussion

Vapour pressureopen allclose all
Key result
Test no.:
#1
Temp.:
ca. 20 °C
Vapour pressure:
ca. 0.01 Pa
Key result
Test no.:
#2
Temp.:
ca. 25 °C
Vapour pressure:
0.017 Pa

Any other information on results incl. tables

A representative weight loss curve of the test item is shown in Figure 3. The results of the isothermal TGA analysis for the test item and the vapour pressure at 20°Cand 25°Care given inTable 3andTable 4.

The vapour pressure regression curve of the log PTof the test item as function of the reciprocal temperatures is shown inFigure 4. The equation of the curve was: log PT= -4182´1/T + 12.3 (r = 0.998, n = 8).

Table 3          
Results of the Vapour pressure Isothermal TGA Analysis

Temperature
[°C]

Weight loss
[µg/min]

νT
[g/cm2/h]

logνT

logPT

PT
[Pa]

70

0.890448

1.06´10-4

-3.97

0.05

1.1

 

0.919489

1.10´10-4

-3.96

0.07

1.2

80

1.76649

2.11´10-4

-3.68

0.43

2.7

 

1.82946

2.18´10-4

-3.66

0.45

2.8

90

3.14177

3.75´10-4

-3.43

0.75

5.6

 

3.31015

3.95´10-4

-3.40

0.78

6.0

100

5.14317

6.14´10-4

-3.21

1.03

11

 

5.38644

6.43´10-4

-3.19

1.05

11

 

Table 4          
Vapour Pressure of the Test Item

Temperature
[°C]

logPT

PT
[Pa]

PT
[mm Hg]

20

-2.00

1.0´10-2

7.5´10-5

25

-1.76

1.7´10-2

1.3´10-4

Applicant's summary and conclusion

Conclusions:
The isothermal TGA effusion method was applied for the determination of the vapour pressure of Dermol TDSA.
The vapour pressure of the test item at 20°C (293K) and 25°C (298K) was:
20°C 25°C
[Pa] [mm Hg] [Pa] [mm Hg]
Test item 0.01 7.5 x 10-5 0.017 1.3 x 10-4
Executive summary:

In this guideline (OECD 104) study, [conducted with GLP certification], the isothermal TGA effusion method was applied for the determination of the vapour pressure of Dermol TDSA.

The vapour pressure of the test item at 20°C (293K) and 25°C (298K) was:

      20°C       25°C

      [Pa]       [mm Hg]       [Pa]       [mm Hg]

Test item       0.01              7.5 x 10-5       0.017       1.3 x 10-4