Registration Dossier

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
ASTM D-445 (Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity)
Deviations:
no
GLP compliance:
no
Type of method:
capillary viscometer (static)
Key result
Temp.:
other: 70°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
19.33
Conclusions:
The substance shows a kinematic viscosity= 19.33 mm/sec2 at 70°C measured with ASTM D445 method.
Executive summary:

The substance shows a kinematic viscosity= 19.33 mm/sec2 at 70°C measured with ASTM D445 method.

Description of key information

The substance shows a kinematic viscosity= 19.33 mm/sec2 at 70°C measured with ASTM D445 method.

Key value for chemical safety assessment

Viscosity:
19.33 mm²/s (static)
at the temperature of:
70 °C

Additional information