Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Biodegradation in water: screening tests

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
biodegradation in water: ready biodegradability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015-07-08 to 2015-08-06
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
Study performed according to standard test guidelines (OECD, EC) and conform GLP requirements. A short (<1 day) disruption of the aeration occurs on day 14, 17 and 19 for the bottle A and on day 24 for all bottles. This does not influence the results of the test. The results can be considered reliable without restriction.
Qualifier:
according to guideline
Guideline:
OECD Guideline 301 B (Ready Biodegradability: CO2 Evolution Test)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method C.4-C (Determination of the "Ready" Biodegradability - Carbon Dioxide Evolution Test)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO DIS 9439 (Ultimate Aerobic Biodegradability - Method by Analysis of Released Carbon Dioxide)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: ISO International Standard 10634 "Water Quality - Guidance for the preparation and treatment of poorly water-soluble organic compounds for the subsequent evaluation of their biodegradability in an aqueous medium"
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material:
* Identification: JNJ-16479489-AAA (T001159)
* Batch: M14IB5308
- Expiration date of the lot/batch: 2016-02-03 (retest date)
- Purity test date: 2015-04-23

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: At room temperature in the dark
- Stability under test conditions: not specified
Oxygen conditions:
aerobic
Inoculum or test system:
activated sludge, domestic, non-adapted
Details on inoculum:
- Source: municipal sewage treatment plant receiving predominantly domestic sewage, 'Waterschap Aa en Maas', 's-Hertogenbosch, The Netherlands.
- Preparation of inoculum for exposure: sludge was kept under continuous aeration until further treatment. Before use, the sludge was allowed to settle (45 minutes) and the supernatant liquid was used as inoculum.
- Concentration of sludge: The concentration of suspended solids was determined to be 4.5 g/L in the concentrated sludge.
- Water filtered: yes. Tap-water purified by reverse osmosis (Milli-RO) and subsequently passed over activated carbon.

Duration of test (contact time):
28 d
Initial conc.:
24 mg/L
Based on:
test mat.
Initial conc.:
12 mg/L
Based on:
other: TOC
Parameter followed for biodegradation estimation:
CO2 evolution
Details on study design:
TEST CONDITIONS
- Composition of medium: test water prepared according to test guidelines, analytical grade salts dissolved in tap-water purified by reverse osmosis (Milli-RO) and subsequently passed over activated carbon. The test item directly weighed into the test flasks, Milli-RO water added, vigorous mixing (vortex). The resulting suspension was added quantitatively to the test medium.
* mineral stock solution A: 8.5 g KH2PO4, 21.75 g K2HPO4, 67.20 g Na2HPO4.12H2O, 0.5 gNH4Cl dissolved in 1 L Milli-Q water, pH 7.4 ± 0.2
* mineral stock solution B: 22.50 g MgSO4.7H2O dissolved in 1 L Milli-Q water
* mineral stock solution C: 36.4 g CaCl2.2H2O dissolved in 1 L Milli-Q water
* mineral stock solution D: 0.25 g FeCl3.6H2O dissolved in 1 L Milli-Q water
* Final test medium: 10 mL of solution A and 1 mL of solutions B, C and D per L of test medium
- Additional substrate: no
- Test temperature: 22-24°C
- pH: 7.5 (measured prior to testing in each test flask before addition of inoculum) and 7.5-7.8 (in each test flask at the end of the incubation period)
- pH adjusted: yes with concentrated HCl
- Aeration of dilution water: The test solutions were continuously stirred during the test.
- Continuous darkness: yes

TEST SYSTEM
- Test flasks: 2 L glass brown coloured bottles
- Number of culture flasks/concentration: 2
* test substance and inoculum: 2 replicates
* inoculum blank: 2 replicates
* positive control: 1 replicate
* toxicity control: 1 replicate
- Method used to create aerobic conditions: A mixture of oxygen (~20%) and nitrogen (~80%) was passed through a bottle, containing 0,5 - 1 L 0,0125 M Ba(OH)2 solution to trap CO2. The synthetic air was sparged through the scrubbing solutions at a rate of ~1-2 bubbles per second ( ~30-100 mL/min). The initial suspension of unspiked test medium and inoculum was aerated with this CO2-free air overnight to purge the system of CO2 prior to testing. This CO2-free air was also used for aeration during the test.
- Details of trap for CO2 and volatile organics if used: 3 CO2-absorbers (bottles filled with 100 mL 0,0125 M Ba(OH)2) were connected in series to the exit air line of eache bottle. The CO2 produced in each test botle reacted with the barium hydroxide in the gas scrubbing bottle and precipitated out as barium carbonate. The amount of CO2 produced was determined by titrating the remaining ba(OH)2 with 0,05 M standardized HCl.

SAMPLING
- Sampling frequency: every second or third day during the first 10 days, and thereafter at least every fifth day until the 28th day
- Sampling method: the absorber bottle closest to the incubation system was sampled each time, the second and third bottle were moved one position closer to the system and a new bottle was added at the end
- On the 28th day, pH of test suspensions was measured and 1 mL of concentrated HCl was added to each bottle. Bottles were aerated overnight to drive off CO2 present in the test suspension. The final titration was made on day 29.

CONTROL AND BLANK SYSTEM
- Inoculum blank: yes, two replicates with only inoculum
- Toxicity control: yes, one replicate with test item, reference substance, and inoculum
- Procedure control: yes, 1 replicate with reference item and inoculum
Reference substance:
acetic acid, sodium salt
Test performance:
In the toxicity control more than 25 % degradation occurred within 14 days (31% based on ThCO2). Therefore, the test substance was assumed to be not inhibitory on microbial activity.
The positive control substance was degraded at least 60 % (72%) within 14 days.
Key result
Parameter:
% degradation (CO2 evolution)
Value:
ca. 8
Sampling time:
28 d
Details on results:
No significant biodegradation of the test item occurred within 28 days of incubation (8%, based on ThCO2 in both bottle). The toxicity controls indicated that the test item did not have an inhibitory effect on the microbial activity.
The criterion for ready biodegradability (at least 60% biodegradation within 10 days of biodegradation exceeding 10%) was not met.
Results with reference substance:
The positive control item was biodegraded by at least 60% (72%) within 14 days, confirming suitability of the activated sludge.
Validity criteria fulfilled:
yes
Interpretation of results:
not readily biodegradable
Conclusions:
A 28-d ready biodegradability test (OECD 301B, modified sturm test) using unadapted activated sludge from a predominantly domestic waste water treatment plant indicated that JNJ-16479489-AAA (T001159) was not readily biodegradable under the conditions of the test (initial concentration 24 mg/L). The test substance showed only 8% biodegradation (test bottle A and B, based on % ThCO2). The test substance did not inhibit microbial activity at the concentration used in the test. The results of the test can be considered reliable without restriction.

Description of key information

One study (Desmares-Koopmans, 2016) was performed according to OECD guideline 301B and regarded as a key study (Klimisch score of 1). A 28-d ready biodegradability test (OECD 301B, modified sturm test) using unadapted activated sludge from a predominantly domestic waste water treatment plant indicated that JNJ-16479489-AAA (T001159) was not readily biodegradable under the conditions of the test (initial concentration 24 mg/L). The results of the test can be considered reliable without restriction.

Key value for chemical safety assessment

Biodegradation in water:
under test conditions no biodegradation observed

Additional information