Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
stability: thermal, sunlight, metals, other
Remarks:
Migrated from section 'Stability: thermal, sunlight, metals'
Type of information:
experimental study
Adequacy of study:
key study
Study period:
19 october 2001
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: see 'Remark'
Remarks:
The test was performed on the basis of the mentioned guidelines with minor modifications. The test was conducted by well experienced staff of a safety laboratory that routinely conducts this type of testing. Protocols for testing procedures are in place.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2001
Report date:
2001

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
DSC
a) DIN 51005
Thermische Analyse (TA), Begriffe, 8/2005
b) DIN 53765
Prüfung von Kunststoffen und Elastomeren, Thermische Analyse, Dynamische
Differenzkalorimetrie (DDK), 3/1994
c) DIN EN ISO 11357-1
Kunststoffe, Dynamische Differenz-Thermoanalyse (DSC), Teil 1: Allgemeine
Grundlagen, 4/2008
d) ISO 11357-2
Plastics – Differential scanning calorimetry (DSC) – Part 2: Determination of glass
transition temperature, 3/1999
e) ISO 11357-3 AMD 1
Kunststoffe – Dynamische Differenzkalorimetrie (DDK) – Teil 3: Bestimmung der
Schmelz- und Kristallisationstemperatur und der Schmelz- und Kristallisationsenthalpie,
7/2005
f) ISO 11357-4
Kunststoffe – Dynamische Differenz-Thermoanalyse (DSC) – Teil 4: Bestimmung
der spezifischen Wärmekapazität, 9/2005
g) ISO 11357-5
Plastics – Differential scanning calorimetry (DSC) – Part 5: Determination of
characteristic reaction-curve temperatures and times, enthalpy of reaction and
degree of conversion, 12/1999

Zersetzungsprüfung im offenen Reagenzglas
a) VDI 2263, Blatt 1
VDI Richtlinien: Staubbrände und Staubexplosionen, Gefahren – Beurteilung –
Schutzmaßnahmen, Untersuchungsmethoden zur Ermittlung von sicherheitstechnischen
Kenngrößen von Stäuben, 5/1990

Zersetzungsprüfung im Autoklaven
a) Prüfung auf Exothermie und Druckaufbau im geschlossenen Gefäß, Mini-Autoklav,
Fa. Kühner AG, incl. Prüfvorschrift und Beschreibung, www.Kuhner.com
b) VDI 2263, Blatt 1
VDI Richtlinien: Staubbrände und Staubexplosionen, Gefahren – Beurteilung –
Schutzmaßnahmen, Untersuchungsmethoden zur Ermittlung von sicherheitstechnischen
Kenngrößen von Stäuben, 5/1990
c) T. Grewer, Thermal Hazards of Chemical Reactions, Industrial Safety Series,
Volume 4, Elsevier Science B. V., Amsterdam, 1994, S. 138 und 139
GLP compliance:
no

Test material

Constituent 1
Reference substance name:
SND 919/II "SND 855 BS"
IUPAC Name:
SND 919/II "SND 855 BS"
Test material form:
solid: particulate/powder
Remarks:
migrated information: particulates
Details on test material:
Molecular weight = 169,250

Molecular formula = C7H11N3S

Results and discussion

For thermal stability study

Operating temperatureopen allclose all
Operating temp.:
< 181 °C
Remarks on result:
other: keine Exothermie bei einer Heizrate von 5°C/min (Differential-Scanning-Calorimetry, DSC)
Operating temp.:
> 140 - < 180 °C
Remarks on result:
other: (Zersetzungsprüfung im offenen Reagenzglas)
Operating temp.:
> 100 °C
Remarks on result:
other: schwacher Druckaufbau bei einer Heizrate von 0,5 °C/min (Zersetzungsprüfung im Autoklaven)
Operating temp.:
> 217 °C
Remarks on result:
other: starker Druckaufbau bei einer Heizrate von 0,5 °C/min (Zersetzungsprüfung im Autoklaven)
Sublimation:
not determined
Transformation products:
not specified

For study on stability to sunlight

Test substance stable to sunlight:
not determined

For study on stability to metals

Test substance stable to metals / metal ions:
not determined

Applicant's summary and conclusion

Conclusions:
Maximaltemperatur der Handhabung aus Sicherheitsgründen (TmaxSi) : ca. 80°C / 24h