Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
31 October 2017 to 19 December 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: isothermal thermogravimetry
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Sponsor and 10037-115-5
- Expiration date of the lot/batch: 06 June 2019
- Purity test date: 06 June 2017
Key result
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
1 Pa
Key result
Test no.:
#2
Temp.:
20 °C
Vapour pressure:
0.008 mm Hg
Key result
Test no.:
#3
Temp.:
25 °C
Vapour pressure:
1.8 Pa
Key result
Test no.:
#4
Temp.:
25 °C
Vapour pressure:
0.013 mm Hg

See attached for detailed results of isothermal TGA analysis

Conclusions:
The isothermal TGA effusion method was applied for the determination of the vapour pressure of Trimethoxyboroxine (TMBX).
The vapour pressure of the test item was: 1.0 Pa (7.6E-3 mmHg) at 20°C (293K) and 1.8 Pa (1.3E-2 mmHg) at 25°C (298K).

Description of key information

The isothermal TGA effusion method was applied for the determination of the vapour pressure of Trimethoxyboroxine (TMBX).

The vapour pressure of the test item was:  1.0 Pa (7.6E-3 mmHg)   at 20°C (293K) and 1.8 Pa (1.3E-2 mmHg) at  25°C (298K).

Key value for chemical safety assessment

Vapour pressure:
1 Pa
at the temperature of:
20 °C

Additional information