Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
3 (not reliable)
Rationale for reliability incl. deficiencies:
other: The result was obtained from a number of publically available sources which have been subject to peer-review and in which the original data sources are traceable. A great deal of variability was seen for this endpoint.

Data source

Referenceopen allclose all

Reference Type:
other: Database
Title:
3-Chloropropane-1,2-diol
Year:
2000
Bibliographic source:
IUCLID dataset, ESIS, European Chemical Bureau
Reference Type:
other: Database
Title:
3-Chloro-1,2-propanediol
Bibliographic source:
IFA Gesitis Substance database
Reference Type:
publication
Title:
Unnamed
Year:
2006
Reference Type:
other company data
Title:
Unnamed

Materials and methods

GLP compliance:
not specified

Test material

Constituent 1
Reference substance name:
3-chloropropane-1,2-diol
EC Number:
202-492-4
EC Name:
3-chloropropane-1,2-diol
Cas Number:
96-24-2
IUPAC Name:
3-chloropropane-1,2-diol
Constituent 2
Reference substance name:
3-Chloro-1,2-propanediol
IUPAC Name:
3-Chloro-1,2-propanediol

Results and discussion

Vapour pressureopen allclose all
Temp.:
25 °C
Vapour pressure:
0.022 hPa
Remarks on result:
other: ESIS result
Temp.:
20 °C
Vapour pressure:
0.01 mBar
Remarks on result:
other: IFA Gestis result
Temp.:
115 °C
Vapour pressure:
13 mBar
Remarks on result:
other: EPA result
Temp.:
20 °C
Vapour pressure:
71 hPa
Remarks on result:
other: Solvay SDS result

Applicant's summary and conclusion

Conclusions:
The vapour pressure data is quite variable but for the purposes of this dossier the value shall be 71hPa at room temperature.