Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
24 June 2021
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Referenceopen allclose all

Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018
Reference Type:
study report
Title:
Unnamed
Year:
2021
Report date:
2021

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Qualifier:
according to guideline
Guideline:
ISO No., other: 11018
Version / remarks:
1997
GLP compliance:
not specified
Remarks:
1 test in GLP and 1 test in non GLP
Type of method:
equilibrium method closed cup
Flash point apparatus:
other: Normalab NPV 310 - This apparatus is in compliance with the following standard: ISO Standard 3679 (September 2004)

Test material

Constituent 1
Reference substance name:
Thuya occidentalis, ext.
EC Number:
290-370-1
EC Name:
Thuya occidentalis, ext.
Cas Number:
90131-58-1
Molecular formula:
not relevant for a UVCB substance
IUPAC Name:
Essential oil of thuya occidentalis obtained from leaves by steam distillation
Test material form:
liquid
Specific details on test material used for the study:
batch number 5087 - production date : 2018 january
batch number n° N° 6967R-2 : 2021

Results and discussion

Flash pointopen allclose all
Key result
Flash point:
62 °C
Atm. press.:
97.3 kPa
Key result
Flash point:
58 °C
Atm. press.:
101.3 kPa

Applicant's summary and conclusion

Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
According to the variability of the sample due to fact that it is an UVCB (essential oil) the flash point of the test item was in the worst case 58 °C ± 1 °C.

Executive summary:

The flash point of the test substance was determined under ISO 11018 method of 1997.

The flash point is below the classification thresholds of 60°C of the CLP regulation 1272/02008. Therefore the susbstance is classified as flammable liquids category 3.