Administrative data

Endpoint:
surface tension
Type of information:
experimental study
Adequacy of study:
key study
Study period:
December 5, 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 115 (Surface Tension of Aqueous Solutions)
GLP compliance:
yes (incl. QA statement)
Type of method:
ring method

Test material

Constituent 1
Test material form:
solid: flakes
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Mitsubishi-Kagaku Foods Corporation; 63281211
- Expiration date of the lot/batch: March 27, 2018
- Purity test date: October 14, 2016

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: 1-10 degrees C in dark, dry conditions

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: Dissolved in ultra-pure water

FORM AS APPLIED IN THE TEST (if different from that of starting material): 1 g/L solution in water

Results and discussion

Surface tension
Key result
Surface tension:
26.3 mN/m
Temp.:
20.1 °C
Conc.:
1 g/L

Any other information on results incl. tables

The test was repeated until the last five determinations had a standard deviation of no more than 0.1 mN/m. The surface tension was corrected with a calibration factor of 1.0203. The absolute deviation was 1.1 mN/m.

Applicant's summary and conclusion

Conclusions:
The surface tension of LMDT is 26.3 mN/m.
Executive summary:

The surface tension of LMDT was tested using the ring method. Two solutions of about 1 g/L LMDT in water were tested. The mean surface tension, with calibration correction, was 26.3 mN/m.