Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Version / remarks:
2006
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Version / remarks:
2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: Knudsen cell
Key result
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
0.008 Pa
Test no.:
#2
Temp.:
25 °C
Vapour pressure:
0.015 Pa
Key result
Test no.:
#3
Temp.:
50 °C
Vapour pressure:
0.22 Pa
Conclusions:
vapour pressure (20°C): 0.008 Pa
Executive summary:

In the Klimisch 1 GLP-study Smekay (2017) determined the vapour pressure of the registered substance according to OECD 104 and EU A.4. using the effusion method (Knudsen cell) At 20"C the vapour pressure was determined to be 0.008 Pa.

The information is considered relevant and reliable for the risk assessment.

Description of key information

vapour pressure (20°C): 0.008 Pa

Key value for chemical safety assessment

Vapour pressure:
0.008 Pa
at the temperature of:
20 °C

Additional information

In the Klimisch 1 GLP-study Smekay (2017) determined the vapour pressure of the registered substance according to OECD 104 and EU A.4. using the effusion method (Knudsen cell) At 20"C the vapour pressure was determined to be 0.008 Pa.