Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Skin sensitisation

Currently viewing:

Administrative data

Endpoint:
skin sensitisation: in vivo (non-LLNA)
Remarks:
Tests on Humans
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Justification for type of information:
Company report outlining positive effects on workers.
Although not a formal clinical study, the information is considered sufficient for classification as Skin Sens 1

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
1996
Report date:
1996

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
Human survey done, survey is limited to the effects experienced by those who have been exposed to OTB directly or indirectly at the Consett site of Thomas Swan & Co. Ltd.
GLP compliance:
no
Type of study:
other: human experience
Justification for non-LLNA method:
Human survey done, survey is limited to the effects experienced by those who have been exposed to OTB directly or indirectly at the Consett site of Thomas Swan & Co. Ltd.

Test material

Constituent 1
Chemical structure
Reference substance name:
1-o-tolylbiguanide
EC Number:
202-268-6
EC Name:
1-o-tolylbiguanide
Cas Number:
93-69-6
Molecular formula:
C9H13N5
IUPAC Name:
1-o-tolylbiguanide
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder

In vivo test system

Test animals

Species:
other: Human

Study design: in vivo (non-LLNA)

Induction
Adequacy of induction:
other: Human observations - workers
Challenge
Adequacy of challenge:
other: Human observations - workers
No. of animals per dose:
19 workers assessed, of whom, several reported adverse effects

Results and discussion

In vivo (non-LLNA)

Results
No. with + reactions:
11
Total no. in group:
19
Clinical observations:
industrial dermatitis
Remarks on result:
positive indication of skin sensitisation
Remarks:
industrial dermatitis

Any other information on results incl. tables

In all but one case, dermatitis occured only after a period of time. All of those affected described the problem as beginning in the "sweaty" areas of the skin e.g around the edges of a dust mask or on the wrist underneath a cuff. Symptoms displayed were, itchiness accompanied by tiny blisters underneath the skin surface followed by the formation of keens and skin loss.

The individual operators used the same level of personal protection throughout their stay in this plant - so a change in level of protection does not seem to be a factor in their eventual development of dermatitis. Therefore the skin problems must have occured because either: -

1) the operators became careless regarding their personal protection or

2) sensitisation to the product developed over a period of time.

If 1) then the dermatitis should have cleared up when they resumed their normal level of care. However, in all cases the skin condition persisted until the operators were removed from the plant. This suggests that sensitisation did take place and that a low level of exposure experienced when wearing the protective equipment was now sufficient to cause an allergic reaction, whereas, previously, the same level of exposure had caused no problems.

Applicant's summary and conclusion

Interpretation of results:
Category 1 (skin sensitising) based on GHS criteria
Conclusions:
On balance, the historical evidence suggests that Casamine OTB may be a skin sensitiser rather than simply an irritant.
Executive summary:

Animal testing cannot be justified on the basis of human data