Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
210 °C
Atm. press.:
101.3 kPa

Preliminary measurement:

 Test item / ml  Temperature / °C  Ignition + /-
 2 50, 100   -
 4  200,210  -
 4  210  +
 4  211  +

Main Test:

The following table shows the results of the main test, and temperatures, where ignition (+) was detected and where not(-).

 Test item / ml   Temperature / °C   Ignition + /-    Barometric pressure / hPa  Flashpont / °C (corrected)
 4 208.0  1004.8   -
 4  209.0  -   1004.8   -
 4    210.0  +   1004.8   210.2
 4  209.5  -   1004.8   -
 4  209.5   -   1004.8   -
 4    209.5  -   1004.8    -
 4    210.0  +   1004.8    210.2
 4    210.0  +   1004.8    210.2
 4   210.0  +   1004.8    210.2
 4     210.0  +   1004.8      210.2

The flash point corrected to 1013 hPa is rounded down wuth an accuracy of 0.5 °C: 210.0 °C

Conclusions:
Flash point of the test item is 210 +/- 0.5 °C at 101.3 kPa.
Executive summary:

The flash point of the test substance was determined in a guideline study according toEU method A.9 by the Setaflash method.

The flash point of the test item is 210 +/- 0.5 °C at 101.3 kPa.

Description of key information

210 +/- 0.5 °C at 101.3 kPa (EU A.9)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
210 °C

Additional information

The flash point of the test substance was determined in a guideline study according to the EU method A.9 by the Setaflash method.

The flash point of the test itemis

210 +/- 0.5 °C at 101.3 kPa.