Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
29 June 2016 - 29 November 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: United Nations (UN), UN no. ST/SG/AC.10/11/Rev.6
Version / remarks:
United Nations (UN), UN no. ST/SG/AC.10/11/Rev.6: Recommendations on the Transport of
Dangerous Goods, Part III: Classification Procedures, Test Methods and Criteria Relating to
Class 2, Class 3, Class 4, Division 5.1, Class 8 and Class 9, Paragraph 32.4.1: “Non-Viscous
Flammable Liquids”, 2009.
Deviations:
no
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: ASTM International, ASTM D7094
Version / remarks:
ASTM International, ASTM D7094: “Standard Test Method for Flash Point by Modified
Continuously Closed Cup (MCCCFP) Tester”, 2012.
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
other: Eraflash tester

Test material

Constituent 1
Chemical structure
Reference substance name:
1-(6-fluoro-3,4-dihydro-2H-1-benzopyran-2-yl)ethan-1-one
Cas Number:
620176-90-1
Molecular formula:
C11H11FO2
IUPAC Name:
1-(6-fluoro-3,4-dihydro-2H-1-benzopyran-2-yl)ethan-1-one
Test material form:
liquid
Details on test material:
- Name of test material (as cited in study reports): JNJ-7928531-AAA (T001481)
- Physical state: liquid
- Appearance: Colourless, light yellow to brown liquid
Specific details on test material used for the study:
- Batch n°: M16AB0419
- Expiration date: 23 September 2016
- Purity: 102.5% (based on GC assay)
- Storage condition of test material: at room temperature

Results and discussion

Flash point
Key result
Flash point:
132 °C
Atm. press.:
1 013.25 hPa

Any other information on results incl. tables

-Preliminary test

The estimated flash-point of the test item was 134.5°C.

-Main study

The difference between the results obtained with the two tests was ≤ 6°C. From this, it was concluded that the flash-point of the test item is the lowest flash-point obtained.

Test   Flash-point [°C]  Lowest flash-point [°C]
 132  132   
2  132

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
Based on the closed cup method which was applied for the determination of the flash-point of JNJ-7928531-AAA (T001481) it is concluded that the flash-point of the test item was 132°C.