Administrative data

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
12 Oct - 18 Oct 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
no
Qualifier:
according to guideline
Guideline:
DIN 51794 (Testing of mineral oil hydrocarbons - Determination of ignition temperature)
Deviations:
no
Qualifier:
according to guideline
Guideline:
IEC 60079-4 (Electrical apparatus for explosive gas atmospheres. Part 4: Method of test for ignition temperature)
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
2,3,3,4,4-pentafluoro-2,5-bis(1,1,1,2,3,3,3-heptafluoropropan-2-yl)-5-methoxyoxolane
EC Number:
812-244-2
Cas Number:
957209-18-6
Molecular formula:
C11H3F19O2
IUPAC Name:
2,3,3,4,4-pentafluoro-2,5-bis(1,1,1,2,3,3,3-heptafluoropropan-2-yl)-5-methoxyoxolane
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Lot # 20003, unit 0022
- Physical state: Clear colourless liquid
- Analytical purity: 99.7%
- Expiration date of the lot/batch: 30 March 2018

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: at room temperature

Results and discussion

Auto-ignition temperature (liquids / gases)
Key result
Auto-ignition temperature:
375 °C
Atm. press.:
> 1 019.7 - < 1 020.2 hPa

Any other information on results incl. tables

The lowest temperature at which ignition of the test item occurred was 377 °C. This temperature was rounded down to the nearest multiple of 5 °C giving an auto-ignition temperature of the test item of 375 °C.

Applicant's summary and conclusion

Conclusions:
The auto-flammability temperature of Novec 7700 is 375 °C at 1019.7 - 1020.2 hPa as determined by EU Method A.15.
Executive summary:

The auto-flammability temperature of Novec 7700 is 375 °C at 1019.7 - 1020.2 hPa and was tested using an auto-ignition temperature apparatus. The study was conducted in accordance with EU Method A.15 and was GLP compliant; therefore the study is considered reliable without restrictions.