Registration Dossier

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
14.04.-02.05.2016
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Principles of method if other than guideline:
Determination of viscosity according to rotational viscometer (dynamic) method with CC27 (SOP STO-051)
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
rotational viscometer (dynamic)
Temp.:
other: 15 °C
Parameter:
dynamic viscosity (in mPa s)
Value:
19
Remarks on result:
other: CK 16-008
Temp.:
other: 50°C
Parameter:
dynamic viscosity (in mPa s)
Value:
4
Remarks on result:
other: CK 16-008
Conclusions:
The viscosity of the substance is 18,5 mPas at 15°C, 3,7 mPas at 50°C (rotational viscometer (dynamic) method with CC27, SOP STO-051) .

Description of key information

The viscosity of the substance is 18,5 mPas at 15°C, 3,7 mPas at 50°C (rotational viscometer (dynamic) method with CC27, SOP STO-051)  .

Key value for chemical safety assessment

Additional information