Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flammable solids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Endpoint:
pyrophoric liquids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
Endpoint:
pyrophoric solids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Endpoint:
self-heating substances / mixtures
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Endpoint:
substances / mixtures which in contact with water emit flammable gases
Data waiving:
other justification
Justification for data waiving:
the study does not need to be conducted because the experience in production or handling shows that the substance does not react with water, e.g. the substance is manufactured with water or washed with water

Description of key information

The substance was not classified as flammable, flammable in contact with water, pyrophoric, and self-heating substance.

 

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

Flammable solids /Pyrophoric solids /Self-heating

The study does not need to be conducted because the substance is a liquid.

 

Pyrophoric liquids

The study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied.  

 

Aerosol

The study does not need to be conducted because the substance is no aerosol.

   

Substance which in contact with water emits flammable gases

The study does not need to be conducted because the experience in production or handling shows that the substance does not react with water, e.g. the substance is manufactured with water or washed with water.

 

Justification for classification or non-classification

Classification, Labelling, and Packaging Regulation (EC) No 1272/2008

Based on available data on flammability, substances in contact with water, aerosols and self-heating and pyrophoric properties, the test item is not classified according to Regulation (EC) No 1272/2008 (CLP), as amended for the eighth time in Regulation (EU) No 2016/918.