Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015-07-13
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Remarks:
The study was conducted in accordance with a relevant test method and in compliance with known quality system (ISO 9001:2008).

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
DIN 51562 Part 1 (Viscometry - Measurement of kinematic viscosity by means of the Ubbelohde viscometer - Part 1: Viscometer specification and measurement procedure)
GLP compliance:
no
Other quality assurance:
other: ISO 9001:2008
Type of method:
capillary viscometer (static)

Test material

Constituent 1
Chemical structure
Reference substance name:
Triacetoxyvinylsilane
EC Number:
223-943-1
EC Name:
Triacetoxyvinylsilane
Cas Number:
4130-08-9
Molecular formula:
C8H12O6Si
IUPAC Name:
2-silylethene-1,1,2-triyl triacetate
Test material form:
other: Liquid

Results and discussion

Viscosity
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
7.643

Any other information on results incl. tables

Results

Test: 1

Capillary tube: Ia

Correction factor: 0.04980

Measured time [s]

Mean value [s]

155

158

154

154

154

155

Viscosity = time (mean value) x correction factor = 7.7190

 

Test: 2

Capillary tube: Ic

Correction factor: 0.02991

Measured time [s]

Mean value [s]

253

253

253

253

253

253

Viscosity = time (mean value) x correction factor = 7.5672

Viscosity at 20°C = 7.6431

Applicant's summary and conclusion

Conclusions:
A kinematic viscosity value of 7.643 mm2/s at 20°C was determined for the substance in accordance with a relevant test method and in compliance with a known quality system (ISO 9001:2008). The result is considered to be reliable.