Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid

Description of key information

For this endpoint, no study was conducted because the substance is a liquid and flash point determination should be used to evaluate the ease of ignition.

Key value for chemical safety assessment

Additional information

Justification for classification or non-classification

The flammability of liquids is determined based on the substance's flash point.

The flash point was experimentally determined to be 134°C at atmospheric pressure.

In accordance with the criteria described in section 2.6.2 of Regulation (EC) No 1272/2008 on the classification, labelling and packaging of substances and mixtures (CLP), a liquid having a flash point of 134°C does not require classification as a flammable liquid.