Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 431-870-3 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
Emergency measure - Inhalation: Remove person from exposure. If the victim is not breathing,
perform mouth to mouth resuscitation. Oxygen may be
administered if breathing is difficult. Show copy of safety data sheet or label to medical staff. Seek immediate medical
attention.
Emergency measure - Eyes: Hold eyelids apart and irrigate affected eye(s) with copious
amounts of water, for at least 15 minutes. Seek immediate
medical attention.
Emergency measure - Skin: Remove contaminated clothing. Wash affected area with copious amounts of water and a mild soap for at least 15
minutes. If irritation persists seek medical attention.
Emergency measure - Ingestion: If ingested, seek medical advice immediately and show the
container or the label. Rinse mouth thoroughly with water.
Induction of vomiting should be considered for significant ingestions if person is conscious and not experiencing
convulsions. Never give anything by mouth to an unconscious
person.
Fire-fighting measures
Recommended extinguishing agent: Use appropriate medium for the underlying cause of the fire
and surrounding environment e.g water,foam or carbon
dioxide.
Product arising from burning: Hazardous decomposition products may consist of COx and NOx products.
Product determined by test: N
Protective equipment: Fire fighters should wear full protective clothing including self contained breathing apparatus, chemical and flame
resistant protective clothing, gloves and boots.
Accidental release measures
Emergency measures in case of spillage: Wear suitable PPE i.e splash goggles, full suit,
coverall,respirator (with high efficiency filters or
cartridges), boots and impermeable gloves. Minimise dust formation by collecting spilled solids using a wet mop, damp
sponge or wet/dry HEPA vacuum. Place collected material into
a suitable labelled container for reclamation or disposal.
Finish cleaning by spreading water and detergent on the
contaminated surface, ventilate area and dispose of
according to local and regional authority requirements.
Handling and storage
Handling: Engineering controls in the form of local ventilation are
provided at the reactor. When they are not sufficient to
control dust exposures, approved respiratory protection to
EN 136 standard should be worn. For manufacturing areas skin protection should be provided in the form of coveralls or
full air suits (conforming to standard EN368) along with
impermeable gloves (conforming to standard EN374). Gloves
should be changed regularly and removed after overt
contamination. Rubber, neoprene or other gloves may be
required if solvents, corrosives or other chemicals are present. Chemical safety glasses should be worn if a full
face respirator is not being worn.
Storage: The substance is stored in a dark, dry area, away from heat
and sunlight. Containers must be correctly labelled and kept
tightly closed when not in use.
Packaging of the substance and or preparation: The substance is packaged in UN approved fibre drums.
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Air transport (UN RTDG/ICAO/IATA)
Shippingopen allclose all
Special provisions / remarks
- Remarks:
- Transport code: Not classified for shipping
Transport: Containers should be secured against falling. Use normal
procedures for transport of industrial chemicals not
considered hazardous for transport.
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Engineering controls in the form of local ventilation are
provided at the reactor. When they are not sufficient to
control dust exposures, approved respiratory protection to
EN 136 standard should be worn. For manufacturing areas skin
protection should be provided in the form of coveralls or
full air suits (conforming to standard EN368) along with
impermeable gloves (conforming to standard EN374). Gloves
should be changed regularly and removed after overt
contamination. Rubber, neoprene or other gloves may be
required if solvents, corrosives or other chemicals are
present. Chemical safety glasses should be worn if a full
face respirator is not being worn.
Stability and reactivity
Danger other than fire: None known
Chemical reaction with water: No changes upon reaction with water
Dust explosion: The material exhibits explosive characteristics if ignited
as a dust cloud. It is susceptible to accumulating static
charges during processing and uncontrolled static discharge
may result in igniting a dust cloud under certain conditions
due to the low minimum ignition energy. Provide suitable
bonding and grounding for containers and process equipment
to control static charges. Powder handling equipment such as
dust collectors, dryers and mills may require additional
protective measures.
Dust explosion determined by test: Y
Disposal considerations
Industry - Possibility of recovery/recycling: Trace quantities are destroyed by biological oxidation in
the on-site and local authority minicipal wastewater
treatment plants. Larger quantities are destroyed by closed
cycle incineration. No practical means of recovery or
recycling are known.
Industry - Possibility of neutralisation: No method of neutralisation is known.
Industry - Possibility of destruction: controlled discharge: Trace quantities are destroyed by biological oxidation in
waste water treatment plants.
Industry - Possibility of destruction - incineration: Incineration is recommended for larger quantities. A
closed-cycle incinerator with scrubbers should be employed.
National and local regulations must be observed.
Industry - Possibility of destruction - water purification: Biological oxidation occurs at waste water treatment plants.
Trace quantities in aqueous washes can be treated in
secondary biological WWTP before discharge to municipal
treatment works. The substance should not normally be
discharged directly to the sewage system or the aqueous
environment.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.