Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Description of key information

in vitro according to OECD 431: Not corrosive (Wingenroth 2016)

Key value for chemical safety assessment

Skin irritation / corrosion

Link to relevant study records
Reference
Endpoint:
skin corrosion: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Dec 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 431 (In Vitro Skin Corrosion: Human Skin Model Test)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Test system:
human skin model
Source species:
human
Cell type:
non-transformed keratinocytes
Cell source:
other: no data available
Source strain:
other: not applicable
Justification for test system used:
according to guideline
Vehicle:
unchanged (no vehicle)
Details on test system:
RECONSTRUCTED HUMAN EPIDERMIS (RHE) TISSUE
- Model used: epiCS (CellSystems, Troisdorf, Germany)
- Tissue Lot number: 100-AE2014-1
- Date of initiation of testing: 01 Dec 2015

TEMPERATURE USED FOR TEST SYSTEM
- Temperature used during treatment / exposure: 3 min (room temperature), 60 min (37°C)
- Temperatur used during post-treatment: after washing, incubation with MTT solution for 3 hours at 37°C

REMOVAL OF TEST MATERIAL AND CONTROLS
- Washing: after the incubation period inserts were washed carefully in PBS
- Observable damage in the tissue due to washing: not applicable
- Modifications to validated SOP: not applicable

MTT DYE USED TO MEASURE TISSUE VIABILITY AFTER TREATMENT / EXPOSURE
- MTT concentration: 1 mg/ml
- Incubation time: 3 hours
- Spectrophotometer: EL808, Bio-Tek
- Wavelength: 570 nm


FUNCTIONAL MODEL CONDITIONS WITH REFERENCE TO HISTORICAL DATA
Reliability of the test was previously confirmed by interlaboratory validation

NUMBER OF REPLICATE TISSUES:
All tests were performed in triplicates for each concentration and each time point

PREDICTION MODEL / DECISION CRITERIA
- The test substance is considered to be corrosive to skin if [complete, e.g. the viability after 3 minutes exposure is less than 50%, or if the viability after 3 minutes exposure is greater than or equal to 50 % and the viability after 1 hour exposure is less than 15%.]
- The test substance is considered to be non-corrosive to skin if [complete, e.g. the viability after 3 minutes exposure is greater than or equal to 50% and the viability after 1 hour exposure is greater than or equal to 15%.]
Control samples:
yes, concurrent negative control
Amount/concentration applied:
TEST MATERIAL
- Amount(s) applied: 50 µl
- Concentration (if solution): undiluted


NEGATIVE CONTROL
- Amount(s) applied: 50 µl
- Concentration (if solution): 0.9% NaCl

Duration of treatment / exposure:
3 min (room temperature), 60 min (37°C)
Duration of post-treatment incubation (if applicable):
after washing, incubation with MTT solution for 3 hours at 37°C
Number of replicates:
three
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
Cell viability after 3 min [%]
Value:
100.79
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
not applicable
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
Cell viability after 60 min [%]
Value:
112.37
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
not applicable
Interpretation of results:
other: not corrosive to skin
Executive summary:

The test substance was evaluated of corrosive properties by using an artificial 3D-Skin model according to OECD guideline 431. The test substance was characterized by no significant impact on cell viability after 3 min. or after the 60 min. period. Thus, the test substance is not to be labeled as corrosive to skin.

Endpoint conclusion
Endpoint conclusion:
adverse effect observed (irritating)

Eye irritation

Link to relevant study records
Reference
Endpoint:
eye irritation: in vitro / ex vivo
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
other:
Reason / purpose for cross-reference:
other:
Endpoint conclusion
Endpoint conclusion:
adverse effect observed (irritating)

Respiratory irritation

Endpoint conclusion
Endpoint conclusion:
adverse effect observed (irritating)

Additional information

The test substance was evaluated of corrosive properties by using an artificial 3D-Skin model according to OECD guideline 431. The test substance was characterized by no significant impact on cell viability after 3 min. or after the 60 min. period. Thus, the test substance is not to be labeled as corrosive to skin. (Wingenroth 2016)

Justification for classification or non-classification

The test substance has no skin corrosive potential according to an in vitro test following OECD guideline 431. Since the test substance is an anhydride a self classification of the test substance according to Regulation (EC) No. 1272/2008 (CLP) is recommended as follows:

Skin Irrit. 2 (H315: Causes skin irritation); Eye Irrit. 2 (H319: Causes serious eye irritation); STOT SE 3 (H335: May cause respiratory irritation)