Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
16 March 2016 to 22 March 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
None
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187: Particle Size Analysis by Laser Diffraction
Principles of method if other than guideline:
None
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
mass based distribution
Specific details on test material used for the study:
Identification: FAT 40066/E TE; Lot: SBL/009/LR6G
Appearance: Dark red powder
Mass median aerodynamic diameter:
74.82 µm
Percentile:
other: L10
Mean:
21.491 µm
Remarks on result:
other: Standard deviation not availlable
Key result
Percentile:
other: L50
Mean:
74.82 µm
Remarks on result:
other: Standard deviation not available
Percentile:
other: L90
Mean:
137.374 µm
Remarks on result:
other: Standard deviation not available
Conclusions:
The median particle size (L50) of FAT 40066/E was found to be 74.820 µm.
Executive summary:

The particle size of FAT 40066 was determined in a study conducted according to the guidelines CIPAC MT 187 and ISO 13320 -1. Laser diffraction method was used for this purpose. Based on the findings of the study, L10, L50 and L90 for the test substance were determined to be 21.491, 74.820 and 137.374 µm, respectively. Hence, the median particle size (L50) of FAT 40066 was determined to be 74.820 µm.

Description of key information

The particle size of FAT 40066 was determined in a study conducted according to the guidelines CIPAC MT 187 and ISO 13320 -1. Laser diffraction method was used for this purpose. Based on the findings of the study, L10, L50 and L90 for the test substance were determined to be 21.491, 74.820 and 137.374 µm, respectively. Hence, the median particle size (L50) of FAT 40066 was determined to be 74.820 µm.

Additional information