Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Biodegradation in water: screening tests

Administrative data

Endpoint:
biodegradation in water: ready biodegradability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2004
Report date:
2005

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method C.4-E (Determination of the "Ready" Biodegradability - Closed Bottle Test)
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
2-amino-2',5-dichlorobenzophenone
EC Number:
220-985-2
EC Name:
2-amino-2',5-dichlorobenzophenone
Cas Number:
2958-36-3
Molecular formula:
C13H9Cl2NO
IUPAC Name:
4-chloro-2-(2-chlorobenzoyl)aniline
Test material form:
solid: particulate/powder
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: L17083
- Expiration date of the lot/batch: March, 2009


STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: ambient temperature, dry

Study design

Oxygen conditions:
aerobic
Inoculum or test system:
sewage, domestic (adaptation not specified)
Details on inoculum:
The inoculum was derived from the effluent of the treatment plant Gemeinschaftsklärwerk Bitterfeld-W olfen receiving predominantly domestic
sewage. A fresh sample was allowed to settle for 1 hour and the decanted effluent was used for the test.
Duration of test (contact time):
28 d
Initial test substance concentration
Initial conc.:
3.7 mg/L
Based on:
test mat.
Parameter followed for biodegradation estimation
Parameter followed for biodegradation estimation:
O2 consumption
Details on study design:
TEST CONDITIONS
- Test temperature: 20°C

SAMPLING
- Sampling frequency: Degradation was followed by oxygen evolution twice a week
Reference substance
Reference substance:
acetic acid, sodium salt

Results and discussion

% Degradationopen allclose all
Parameter:
% degradation (O2 consumption)
Value:
1
Sampling time:
1 d
Parameter:
% degradation (O2 consumption)
Value:
2
Sampling time:
3 d
Parameter:
% degradation (O2 consumption)
Value:
4
Sampling time:
6 d
Parameter:
% degradation (O2 consumption)
Value:
0
Sampling time:
10 d
Parameter:
% degradation (O2 consumption)
Value:
0
Sampling time:
28 d

BOD5 / COD results

Results with reference substance:
Kinetic of control substance:
51% after 3 days, 68% after 10 days, 76% after 13 days

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Interpretation of results:
other: not readily biodegradable
Conclusions:
In the present study no marked oxygen uptake by the test item was measured. The pass Ievel for ready biodegradation (60 per cent degradation) was not reached. For this reason in the test for ready biodegradability the test item seems to be not readily biodegradable.