Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2014-02-18 to 2014-07-02
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Dynamic viscosity of test material:
32.7 mPa*s at 20°C
Key result
Flash point:
188 °C
Atm. press.:
1 013 hPa

  Flash point at atmospheric pressure [°C] 

Flash point, corrected to a pressure of 1013 hPa [°C] 

 Preliminary test  190  190
 First run

 187

 187

 Second run

 189

 189

 Mean value  

 188

Interpretation of results:
GHS criteria not met
Conclusions:
Flash point (1013 hPa): 188 °C
Executive summary:

The flash point of the test item was determined according to EU test method A.9 [Council Regulation (EC) No 440/2008, Official Journal L 142/1 2008] with the Pensky-Martens method (closed cup).

Description of key information

Flash point (1013 hPa): 188 °C

Key value for chemical safety assessment

Flash point at 101 325 Pa:
188 °C

Additional information