Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
GLP compliance:
yes (incl. QA statement)
Type of method:
thermal analysis

Test material

Constituent 1
Chemical structure
Reference substance name:
8-(benzoyloxy)naphthalen-1-yl benzoate
EC Number:
810-797-4
Cas Number:
331711-99-0
Molecular formula:
C24 H16 O4
IUPAC Name:
8-(benzoyloxy)naphthalen-1-yl benzoate
Constituent 2
Reference substance name:
Thane 003-6
IUPAC Name:
Thane 003-6
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder
Details on test material:
Name of test material (as cited in study report): 1,8-Naphthalenediol , 1,8-dibenzoate
Physical state: solid
Analytical purity: 99.0 g / 100 g via 1H-NMR spectroscopy
Lot/batch No.: CHPC021814NDB
Expiration date of the lot/batch: Jul29, 2014
Storage condition of test material: Room temperature, protected from moisture

Results and discussion

Melting / freezing point
Melting / freezing pt.:
179 °C
Atm. press.:
1 013.25 hPa

Any other information on results incl. tables

Results in detail

Melting temperature

Determination

Onset temperature

[°C]

Peak temperature

[°C]

A

179.5

181.6

B

179.3

181.2

Mean value

179

181

The estimated accuracy is ± 1 °C.

Observed thermic processes

After the 1 st heating the test item did not recrystallize in the same way. A sharp endothermic peak was found at 159 °C onset temperature in the 2nd heating. This might be the melting of another polymorphic form of the test item.

In order to survey the thermic behavior of the test item a preliminary TG/DTA-Test (non-GLP) was run up to 600 °C.

An endothermic peak starting at about 250 °C with a weight loss of 98 % at 400 °C showed the vaporization of the test item.

Applicant's summary and conclusion