Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From June 30, 1999 to October 05, 1999
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes
Test procedure:
burning rate test: preliminary screening test
Moisture (wt %):
8.8
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

The substance could not be ignited with a flame. The main test is unnecessary because the test substance could not be ignited.

Interpretation of results:
GHS criteria not met
Conclusions:
Under the test conditions, test substance is not a readily combustible solid.
Executive summary:

A study was performed to determine the flammability of test substance according to EU Method A.10 in compliance with GLP.

The substance could not be ignited with a flame. The main test is unnecessary because the test substance could not be ignited.

Under the test conditions, test substance is not a readily combustible solid.

Description of key information

Test substance is not a readily combustible solid.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

A study was performed to determine the flammability of test substance according to EU Method A.10.

The substance could not be ignited with a flame. Main test is unnecessary because the test substance could not be ignited. The test substance is not a readily combustible solid (Smeykal H, 1999).

No classification is required for flammability according to EC criteria (67/548/EEC) and according to CLP criteria (EC 1272/2008).

Justification for classification or non-classification

A study was performed to determine the flammability of test substance according to EU Method A.10.

The substance couldn't be ignited with a flame. Main test is unnecessary because the test substance couldn't be ignited. The test substance is not a readily combustible solid (Smeykal H, 1999).

No classification is required for flammability according to EC criteria (67/548/EEC) and according to CLP criteria (EC 1272/2008).