Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: - | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Additional physico-chemical information
Administrative data
- Endpoint:
- other: analytical method
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- From 24 August 2015 to 06 November 2015
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: Study performed according to recognized international guideline and under GLP.
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 015
- Report date:
- 2015
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- other: SANCO/3030/99 rev. 4 from 11/07/00
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
Test material
- Reference substance name:
- Tetrakis(hydroxymethyl)phosphonium sulphate (2:1) and its oligomerisation products with urea
- Molecular formula:
- Not applicable
- IUPAC Name:
- Tetrakis(hydroxymethyl)phosphonium sulphate (2:1) and its oligomerisation products with urea
- Test material form:
- other: dried sample
- Details on test material:
- - Name of test material (as cited in study report): Phosphonium, tetrakis (hydroxymethyl)-sulphate(2:1); polymer with urea
For others details see the section Confidential details on test material
Constituent 1
Results and discussion
- Results:
- The analytical method shows a good specificity for Active Ingredients analysis.
The relation between the quantity of Active Ingredients and the equivalent volume of iodine is linear within the range of 19.47 to 142.88 mg of Active Ingredients.
The accuracy results of Active Ingredients are in conformity with the Guidelines requirements. Indeed, the recovery results should be in the range 98-102% and they are experimentally between 99.3% and 100.3%
The concentration of Active Ingredients in the test item was equal to 94.0% w/w or 940 g/kg. In the case of Active Ingredients, the precision was acceptable as the R.S.D was lower than the results of the modified Horwitz equation (0.54%< 1.35%).
The limit of detection (LOD) of Active Ingredients was defined as 1.64 mg of Active Ingredients.
The limit of quantification (LOQ) of Active Ingredients was defined as 4.98 mg of Active Ingredients.
Any other information on results incl. tables
Specificity:
In the test item and in the reference item, the initial solution is colorless and become dark/purple at the point of equivalence. Nearly the same volume of 0.05N iodine solution is necessary to reach the point of equivalence in both items.
In the solvent blank the initial solution was colorless. After addition of 0.1 mL of the 0.05 iodine solution, a coloration dark/purple was observed. As this volume of 0.1 mL is lower (<1%) of the volume required to reach the point of equivalence in the test items, the specificity was defined.
Additionally, no interferences of the detection and quantification of Active Ingredients in the test item solutions is observed.
Linearity:
The correlation coefficient of the calibration curve obtained by the analysis of 5 test item solutions is: r² = 0.9999.
The concentration of the test item solutions used for the calibration curve are between 19.47 and 142.88 mg.
Accuracy:
The recovery rates of Active Ingredients in the two spiked solutions of test item are between 99.3 and 100.3%.
Precision:
The mean content of the five analysed test item solutions is 94.0% (w/w).
The standard deviation related to the mean content is 0.5% (w/w) and the Relative Standard Deviation (RSD) is 0.54%.
The modified Horwitz equation is verified. Indeed :
R.S.D < 2(1 -0.5*log C)*0.67
0.54 < 2(1 -0.5*log 0.94)*0.67
0.54 < 1.35
According to the guideline requirement, the precision of the analytical method is therefore considered to be fulfilled.
Limit of detection (LOD) and limit of quantification (LOQ):
The limit of detection (LOD) and the limit of quantification (LOQ) are defined through the regression curve.
Mass (mg) | |
LOD | 1,64 of active ingredients |
LOQ | 4,98 of active ingredients |
Applicant's summary and conclusion
- Conclusions:
- The analytical method is validated for the test item between 19.47 and 142.88 mg of Active Ingredients in water.
- Executive summary:
The validation of an analytical method (titration method) for the determination of Active Ingredients in dried extract of Phosphonium, tetrakis (hydroxymethyl)-sulphate(2:1); polymer with urea will be done in compliance with the SANCO/3030/99 rev.4. No deviation from the guideline was observed in this GLP study.
The analytical method is validated by definition of the specificity, the linearity, the accuracy, the precision and the limit of detection and the limit of quantification of the method.
The analytical method shows a good specificity for Active Ingredients analysis.
The relation between the quantity of Active Ingredients and the equivalent volume of iodine is linear within the range of 19.47 to 142.88 mg of Active Ingredients.
The accuracy results of Active Ingredients are in conformity with the Guidelines requirements. Indeed, the recovery results should be in the range 98-102% and they are experimentally between 99.3% and 100.3%
The concentration of Active Ingredients in the test item was equal to 94.0% w/w or 940 g/kg. In the case of Active Ingredients, the precision was acceptable as the R.S.D was lower than the results of the modified Horwitz equation (0.54%< 1.35%).
The limit of detection (LOD) of Active Ingredients was defined as 1.64 mg of Active Ingredients.
The limit of quantification (LOQ) of Active Ingredients was defined as 4.98 mg of Active Ingredients.
The analytical method is validated for the test item between 19.47 and 142.88 mg of Active Ingredients in water.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.