Registration Dossier

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Acceptable, well documented company data which meets basic scientific principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2003
Report date:
2003

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
GLP compliance:
yes

Test material

Constituent 1
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder
Details on test material:
Chemical identifier as per section 1.1 and 1.2.
Batch: 021302
Conditions for storage: Ambient temperature.

Test organisms

Test organisms (species):
activated sludge

Results and discussion

Any other information on results incl. tables

The test substance inhibited the respiration of the activated sludge in a concentration dependent extent. The highest obtained inhibition was 94.8%.

The pH of the incubation mixture after the 3 hours incubation was between 8.29 and 8.35. The test substance did not influence the pH. The following EC values for the test substance were obtained:

EC20: 14 mg/L ( EC-Value) 6 -22mg/L ( 95% confidence limits)

EC50: 37mg/L ( EC- value) 21 to 53 mg/L ( 95% confidence limits)

EC80: 103mg/L ( EC- value) 73 to 133 mg/L ( 95% confidence limits)

Applicant's summary and conclusion

Conclusions:
The test substance inhibited the respiration of the activated sludge in a concentration dependent extent. The highest obtained inhibition
was 94.8%.
The pH of the incubation mixture after the 3 hours incubation was between 8.29 and 8.35. The test substance did not influence the pH.
The following EC values for the test substance were obtained:
EC20: 14 mg/L ( EC-Value) 6 -22mg/L ( 95% confidence limits)
EC50: 37mg/L ( EC- value) 21 to 53 mg/L ( 95% confidence limits)