Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Flash point: 121 - 185 C (ASTM D3278)

Key value for chemical safety assessment

Additional information

A reliable flash point of 121 - 185°C has been determined for four samples of Crude Tall Oil (CTO) using an appropriate test method (ASTM D3278). The lowest flash point data obtained using a close cup method are selected as key study for the purpose of classification and labelling. In a published literature, a flash point range of 385 - 420 F (196 - 216°C) was reported for CTO using open cup (Cleveland) method according to D-803 ASTM test guideline.