Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009-08-11 to 2009-08-21
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
other: DIN ISO 4497
Deviations:
no
Principles of method if other than guideline:
The dry sieve test is performed according to DIN ISO 4497 using a 1mm and 100 µm sieve to separate bigger particles (>1 mm) from smaller particles and the particulate matter (<100 ). Laser diffraction of the particulate matter was not performed using the method OECD 110 particle size distribution.
GLP compliance:
yes (incl. QA statement)
Remarks:
signed 2006-01-11
Type of method:
sieving
Type of distribution:
volumetric distribution
Specific details on test material used for the study:
Appearance: orange, small crystals with bigger particles and powder
Remarks on result:
not measured/tested
Percentile:
D50
Remarks on result:
not measured/tested
No.:
#1
Size:
> 1 mm
Distribution:
0.6 %
No.:
#2
Size:
> 0.1 - < 1 mm
Distribution:
94.7 %
No.:
#3
Size:
< 100 µm
Distribution:
5.2 %

The complete sample (1074.45 g) was sieved manually using a 1 mm mesh sieve. Approximately 384 g of the fraction smaller then 1 mm were sieved using a sieve of 100 µm mesh. The resulting fractions were quantified gravimetrically.

Particle fraction

Initial Weight

Weight

Amount in %

Share bigger than 1 mm

1074.45 g

6.52 g

0.6 %

<1 mm but bigger than 100 µm

383.81 g

363.45

94.7 %

Particulate matter (<100 µm)

 

20.11

5.2 %

Total

 

 

100.5 %

A dry sieve test was performed using two sieves with a mesh size of 1 mm and 100 µm respectively. The particle size distribution was 0.6 % particles bigger than 1 mm, 94.7 % of particles <1 mm and >100 µm and 5.2 % of particulate matter (<100 µm).

At the request of the sponsor, laser diffraction was not performed because sodium (VI) dichromate is a known carcinogen and therefore a more detailed investigation of the particulate matter (<100  µm) would not reveal significantly new information relevant for risk assessment.

Conclusions:
The particle size distribution was 0.6 % particles bigger than 1 mm, 94.7 % of particles <1 mm and >100 µm and 5.2 % of particulate matter (<100 µm).

Description of key information

The particle size distribution was 0.6 % particles bigger than 1 mm, 94.7 % of particles <1 mm and >100 µm and 5.2 % of particulate matter (<100 µm).

Additional information